Comparison between 3-dimensional cranial ultrasonography and conventional 2-dimensional cranial ultrasonography in neonates: impact on reinterpretation
نویسندگان
چکیده
PURPOSE The aim of this study was to evaluate impact of 3-dimensional cranial ultrasonography (3DUS) on reinterpretation of cranial ultrasonography images in neonates in comparison with 2-dimensional cranial ultrasonography (2DUS). METHODS We retrospectively enrolled 50 young infants who simultaneously underwent both 2DUS and 3DUS scanning from February to March 2015. Two pediatric radiologists independently reviewed both scans for overall image quality on a 5-point scale. Five features were evaluated in both scans: the presence of germinal matrix hemorrhage (GMH), intraventricular hemorrhage (IVH), ventriculomegaly (VM), abnormality of periventricular echogenicity (PVE), and focal parenchymal lesions (FL). The concordance rate between the two scanning modes was calculated. The confidence level for each finding on a 3-point scale and the scanning time were compared between the two scanning modes. Interobserver agreement was evaluated using kappa statistics. RESULTS Both scans demonstrated similar overall image quality in terms of reinterpretation (mean scores for 2DUS and 3DUS, 4.0±0.5 and 4.0±0.7 in reviewer 1, 3.9±0.6 and 4.0±0.8 in reviewer 2, respectively). GMH, IVH, VM, and FL showed perfect concordance, while PVE showed a concordance rate of 91.4% between the two modes by both reviewers. 3DUS was associated with a higher diagnostic confidence in the evaluation of GMH, IVH, and FL than 2DUS (P<0.05) for both reviewers. For PVE, 3DUS received a significantly higher confidence score than 2DUS from one of the reviewers. The mean scanning time for 2DUS and 3DUS was 92.75 seconds and 36 seconds, respectively. Interobserver agreement for qualitative scoring was almost perfect. CONCLUSION In reinterpretation, 3DUS showed very high concordance with 2DUS and a similar image quality. 3DUS also increased diagnostic confidence for several image findings and significantly decreased scan time.
منابع مشابه
Evaluation of Six-Dimensional Cranial Target Positioning Accuracy in Two Different Immobilization Methods Using Exactrac System
Introduction: The aim of this study was to determine the accuracy of two different immobilization methods in patient positioning in cranial radiotherapy. The six-dimensional (6D) target localization accuracy of using a dedicated stereotactic mask was compared with that of a conventional head mask by the ExacTrac system. Material and Methods: ...
متن کاملThree-dimensional Volumetric Ultrasonography of Enlarged Adrenal Gland in Dog
Objective: Detection and evaluation of adrenal glands are complex problems in conventional ultrasonography in dogs. Using three-dimensional (3D) ultrasonography (US) in adrenal gland volume evaluation can add new potential for further adrenal studies. Design: Descriptive study Animals: a total of 10 mix breed dogs Procedures: The dogs underwent two dimensional (2D) and 3D US of the adrenal g...
متن کاملUltrasonographic Volumetry of the Canine Thyroid Gland: A Comparison of 2D, 3D Ultrasonography and Real Gland Volume
Objective: to compare the estimated thyroid volume, as determined by two-dimensional (2D) and three-dimensional (3D) ultrasonography, with real volume. Design: Descriptive Study Animals: A total of 7 mixed breed dogs Procedures: On 2D ultrasound, the thyroid volume is estimated by the ellipsoid equation and on 3D ultrasound; it is estimated by outlining the boundaries of the thyroid lobe in ...
متن کاملUse of three-dimensional ultrasonography of the eye and measurement of optical long axis in dog
This study was conducted to determine the use of three-dimensional ultrasonography (3DU) in ocular imaging of the dog and measuring of its optical axis. 12 healthy mixed-breed dogs including 6 males and 6 females were studied. 3DU of the eyes were done using a 5–12 MHz linear trapezoid transducer. 3DU of the eyes were evaluated and the normal optical long axis through a line between the cornea ...
متن کاملUltrasound detection of posterior fossa abnormalities in full-term neonates.
Routine cranial ultrasonography, using the anterior fontanelle as acoustic window enables visualization of the supratentorial brain structures in neonates and young infants. The mastoid fontanelle enables a better view of the infratentorial structures, especially cerebellar hemorrhage in preterm infants. Reports on the usefulness and reliability of cranial ultrasonography using the mastoid font...
متن کامل