Simulation Analysis and Experiment of Variable-Displacement Asymmetric Axial Piston Pump

نویسندگان

  • Youshan Gao
  • Jie Cheng
  • Jiahai Huang
چکیده

The variable displacement pump control system has greater energy-saving advantages and application prospects than the valve control system. However, the variable displacement pump control of differential cylinder is not concurrent with the existing technologies. The asymmetric pump-controlled cylinder is, therefore, used to balance the unequal volume flow through a single rod cylinder in closed-circuit system. This is considered to be an effective method. Nevertheless, the asymmetric axial piston pump (AAPP) is a constant displacement pump. In this study, variable-displacement asymmetric axial piston pump (VAPP) is investigated according to the same principle used in investigating AAPP. This study, therefore, aims at investigating the characteristics of VAPP. The variable-displacement output of VAPP is implemented by controlling the swash plate angle with angle feedback control circuit, which is composed of a servo proportional valve and an angular displacement sensor. The angular displacement sensor is connected to the swash plate. The simulation model of VAPP, which is set up through the ITI-SimulationX simulation platform, is used to predict VAPP’s characteristics. The purpose of implementing the experiment is to verify the theoretical results. Both the simulation and the experiment results demonstrated that the swash plate angle is controlled by a variable mechanism; when the swash plate angle increases, the flow of Port B and Port T increases while the response speed of Port B and Port T also accelerates. When the swash plate angle is constant, the flow of Port B and Port T increases along with the increase of pump speed, although the pressure-response speed of Port B is faster than that of Port T. Consequently, the flow pulsation of Port B and Port T tends to decrease gradually along with the increase of pump speed. When the pressure loaded on Port B equals to that of Port T, the flow ripple cycle of Port B is longer than that of Port T, whereas the peak flow of Port B is higher than that of Port T. Since the flow ripple of Port T is bigger than that of Port B, Port T should be connected to the low pressure sides or the oil tank so that it does not affect VAPP’s performance. Further, to avoid the backflow of VAPP from Port T to Port B, Port T cannot be loaded alone, and the loading pressure of Port T also cannot exceed that of Port B.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation research on distribution method of axial piston pump utilizing pressure equalization mechanism

Noise reduction in axial piston pumps has been attempted by many researchers with different design approaches and techniques. However, most traditional structures on valve plate for noise reduction are at the cost of efficiency to different extent. In this article, a new distribution method with pressure equalization mechanism composed of check valve and pressure recuperation chamber is discuss...

متن کامل

An improvement on a method for nonlinear pressure control of self-supplied variable displacement axial piston pumps

A method for pressure control of self-supplied variable displacement axial piston pumps is considered. By analyzing the mathematical model, a crucial part of the nonlinear system is found to be a piecewise linear function. A control strategy composed of an overall feedforward control and a feedback control is given using the smooth hinge function. Compared with current switching feedforward con...

متن کامل

An Artificial Neural Network Flow Control of Variable Displacement Piston Pump with Pressure Compensation

One of the most important components in hydraulic circuits is the pump that generates hydraulic supply at constant pressure. The performance and the versatility of a variable displacement piston pump are, to a large extent, determined by its controller. Upgrading of existing controllers is considered one of the major means of improving the characteristics of the pump. The dynamic performance of...

متن کامل

The Force Control of a Novel Variable Rotational Speed Hydraulic Pump-Controlled System Using Adaptive Fuzzy Controller with Self-Tuning Fuzzy Sliding-Mode Compensation

The conventional hydraulic valve-controlled systems have high response but low energyefficiency. Hydraulic pump-controlled servo systems have high energy efficiency. However, the conventional pump-controlled systems, which are altered by displacement via variable displacement pumps, have lower response. This paper aims to investigate the force control performance of the high response electro-hy...

متن کامل

Modeling and Performance Improvement of the Constant Power Regulator Systems in Variable Displacement Axial Piston Pump

An irregular performance of a mechanical-type constant power regulator is considered. In order to find the cause of an irregular discharge flow at the cut-off pressure area, modeling and numerical simulations are performed to observe dynamic behavior of internal parts of the constant power regulator system for a swashplate-type axial piston pump. The commercial numerical simulation software AME...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017