Spitzer Space Telescope: Dark Current and Total Noise Prediction for InSb Detector Arrays in the Infrared Array Camera (IRAC) for the Post-Cryogen Era
نویسندگان
چکیده
During the expected 5+ years of operation, the Spitzer Space Telescope is and will continue to produce outstanding infrared images and spectra, and greatly further scientific understanding of our universe. The Spitzer Space Telescope’s instruments are cryogenically cooled to achieve low dark current and low noise. After the cryogens are exhausted, the Spitzer Space Telescope will only be cooled by passively radiating into space. The detector arrays in the IRAC instrument are expected to equilibrate at approximately 30K. The two shortest wavelength channels (3.6 and 4.5 micron) employ InSb detector arrays and are expected to function and perform with only a modest degradation in sensitivity. Thus, an extended mission is possible for Spitzer. We present the predicted dark current, noise, quantum efficiency and image residuals for the 3.6 and 4.5 micron IRAC channels in the post-cryogen era.
منابع مشابه
InSb arrays for IRAC (InfraRed Array Camera) on SIRTF (Space Infrared Telesope Facility)
SIRTF requires detector arrays with extremely high sensitivity, limited only by the background irradiance. Especially critical is the near infrared spectral region around 3 μm, where the detector current due to the zodiacal background is a minimum. IRAC has two near infrared detector channels centered at 3.6 and 4.5 μm. We have developed InSb arrays for these channels that operate with dark cur...
متن کاملThe Infrared Array Camera (IRAC) for the Space Infrared Telescope Facility (SIRTF)
The Space Infrared Telescope Facility (SIRTF) contains three focal plane instruments, one of which is the Infrared Array Camera (IRAC). IRAC is a four-channel camera that provides simultaneous 5.12 × 5.12 arcmin images at 3.6, 4.5, 5.8, and 8 microns. The pixel size is 1.2 arcsec in all bands. Two adjacent fields of view in the SIRTF focal plane are viewed by the four channels in pairs (3.6 and...
متن کاملImpressive Reduction of Dark Current in InSb Infrared Photodetector to achieve High Temperature Performance
Infrared photo detectors have vast and promising applications in military,industrial and other fields. In this paper, we present a method for improving theperformance of an infrared photodetector based on an InSb substance. To achieve goodperformance at high temperatures, thermal noise and intrusive currents should bereduced. For this purpose, a five-layer hetero structu...
متن کاملIntra-Pixel Gain Variations and High-Precision Photometry with the Infrared Array Camera (IRAC)
The Infrared Array Camera (IRAC) on the Spitzer Space Telescope has been used to measure < 10−4 temporal variations in point sources (such as transiting extrasolar planets) at 3.6 and 4.5μm. Due to the under-sampled nature of the PSF, the warm IRAC arrays show variations of as much as 8% in sensitivity as the center of the PSF moves across a pixel due to normal spacecraft pointing wobble and dr...
متن کاملOptimal Merging of Point Sources Extracted from Spitzer Space Telescope Data in Multiple Infrared Passbands Versus Simple General Source Association
For collating point-source flux measurements derived from multiple infrared passbands of Spitzer-Space-Telescope data – e.g., channels 1-4 of the Infrared Array Camera (IRAC) and channels 1-3 of the Multiband Imaging Photometer for Spitzer (MIPS) – it is best to use the ‘bandmerge’ software developed at the Spitzer Science Center rather than the relatively simple method of general source associ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006