Methemoglobinemia with the use of benzocaine spray for awake fiberoptic intubation.
نویسندگان
چکیده
We report a case in which the use of benzocaine spray to facilitate awake fiber optic intubation (FOI) in a patient with a difficult airway caused methemoglobinemia intraoperatively. Local benzocaine was sprayed to numb the patient's airway for a total time of one second, fifteen minutes later SpO2 decreased to 85% on the pulse oximeter. Arterial blood gas (ABG) showed a MetHb of 24.6% of total Hemoglobin. The patient was successfully treated with methylene blue intravenously and recovered uneventfully. Small amounts of local benzocaine sprayed to numb the airway can cause significant methemoglobinemia that requires immediate recognition and appropriate management.
منابع مشابه
Suspected methemoglobinemia following awake intubation: one possible effect of benzocaine topical anesthesia--a case report.
Methemoglobinemia is a potential negative side effect associated with the use of benzocaine for topical anesthesia. A healthy patient admitted for an outpatient orthopedic procedure developed the clinical symptomatology of methemoglobinemia after topicalization of the airway with benzocaine. The patient subsequently responded to appropriate treatment and was fit for discharge the same day. Meth...
متن کاملBenzocaine-induced methemoglobinemia.
A case is reported in which a patient developed methemoglobinemia-induced cyanosis while under general anesthesia during surgery for multiple fascial space infections. The cause of methemoglobinemia was 20% benzocaine spray used for local anesthesia before intubation. Acutely developing methemoglobinemia is infrequently encountered in clinical practice. When confronted with cyanosis in the abse...
متن کاملReported adverse event cases of methemoglobinemia associated with benzocaine products.
BACKGROUND Methemoglobinemia (MHb) is characterized by abnormal levels of oxidized hemoglobin that cannot bind and transport oxygen. When induced by benzocaine anesthetic spray and other chemicals, it can result in cyanosis and life-threatening complications. METHODS From 818 439 adverse event reports received by the US Food and Drug Administration from November 1997 through March 2002, we ex...
متن کاملMethemoglobinemia: an unusual cause of postoperative cyanosis.
Methemoglobinemia, although rare, must be considered in surgical patients presenting with acute respiratory distress and cyanosis. We report two cases of methemoglobinemia in patients undergoing aortic reconstruction. The first patient developed methemoglobinemia while on a nitroglycerin infusion, and the second after receiving benzocaine spray before intubation. Both patients were treated with...
متن کاملSevere methemoglobinemia from topical anesthetic spray: case report, discussion and qualitative systematic review.
Few health care professionals realize that topical anesthetic spray can cause methemoglobinemia. We describe a 56-year-old woman who was transferred to our emergency department when severe cyanosis and chest pain developed after administration of topical oropharyngeal benzocaine and lidocaine during outpatient endoscopy. Investigations revealed a methemoglobin level of 51%. Despite rapid diagno...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Middle East journal of anaesthesiology
دوره 22 3 شماره
صفحات -
تاریخ انتشار 2013