Effect of the choice of WHO International Reference Preparation for thromboplastin on International Normalised Ratios.
نویسندگان
چکیده
AIMS To compare the International Normalised Ratio (INR) obtained directly with the two types of WHO plain International Reference Preparation for thromboplastin in patients treated with coumarin. METHODS Prothrombin times were performed in parallel at four centres using WHO human plain IRP (BCT/253) and rabbit plain IRP (RBT/79). Sixty patients and 20 normal controls were tested at each centre. Differences in INR among the centres were assessed by one factor, analysis of variance. The bias for each centre was assessed by the t test. RESULTS At all four centres higher INRs were consistently found with the rabbit plain reagent. Two of the centres showed significantly greater bias. CONCLUSIONS There was a small but significant difference in INR results obtained directly with these two reference reagents at all four centres (mean 7.35%). This in part may result from the different responsiveness of the two IRP to the coumarin defect or to imprecision of the original ISI calibrations of the two plain WHO IRP. The findings support the adoption of a single master IRP, in accord with WHO recommendations, which would resolve the present anomalous situation.
منابع مشابه
Effect of international sensitivity index (ISI) of thromboplastins on precision of international normalised ratios (INR)
The contribution of the thromboplastin international sensitivity index (ISI) to the interlaboratory coefficient of variation (CV) of the international normalised ratio (INR) with individual reagents was assessed. In theory the precision of the INR should increase with lower ISI values. An empirical relation has been established between the ISI, the INR, and its CV for two rabbit thromboplastins...
متن کاملEuropean Concerted Action on Anticoagulation. A multicentre calibration study of WHO international reference preparations for thromboplastin, rabbit (RBT/90) and human (rTF/95).
A 10 centre calibration was performed after six years to determine the international sensitivity index (ISI) of rTF/95 relative to RBT/90, and to assess any international normalised ratio (INR) bias compared with the original multicentre calibration. After exclusion of one outlying centre, the follow up calibration gave a mean ISI for rTF/95 of 0.99, which although a small difference, is signif...
متن کاملInternational collaborative study for the calibration of a proposed reference preparation for thromboplastin, human recombinant, plain. On behalf of the Subcommittee on Control of Anticoagulation.
Stocks of the International Reference Preparation (IRP) for thromboplastin, human, plain, coded BCT/253 and held by the World Health Organization (WHO) are nearly exhausted and must be replaced. For practical reasons the choice of the replacement candidate was restricted to two available human recombinant preparations which were coded as X/95 and Y/95 and calibrated in an international collabor...
متن کاملField study of lyophilised plasmas for local prothrombin time calibration in The Netherlands.
AIM To assess the effect of a lyophilised calibrant plasma procedure on the international normalised ratio (INR) and its interlaboratory variation. METHODS INR equivalent values were assigned to five lyophilised plasmas (one from normal donors and four from coumarin treated patients) by a reference laboratory using three calibrated thromboplastin reagents. The calibrant plasmas and five artif...
متن کاملScreening INR deviation of local prothrombin time systems.
AIM To assess the reliability of local international normalised ratios (INR) using a set of three international reference preparation (IRP) certified freeze dried plasmas. METHODS 55 centres in the United Kingdom and the Republic of Ireland participated; 36 centres employed coagulometers and 19 a manual prothrombin time technique, all with the same batch of routine commercial thromboplastin. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 46 1 شماره
صفحات -
تاریخ انتشار 1993