Mapping Glaucoma Patients' 30-2 and 10-2 Visual Fields Reveals Clusters of Test Points Damaged in the 10-2 Grid That Are Not Sampled in the Sparse 30-2 Grid

نویسنده

  • Ryo Asaoka
چکیده

PURPOSE To cluster test points in glaucoma patients' 30-2 and 10-2 visual field (VF) (Humphrey Field Analyzer: HFA, Carl Zeiss Meditec, Dublin, CA) in order to map the different regions damaged by the disease. METHOD This retrospective study included 128 eyes from 128 patients. 142 total deviation (TD) values (74 from the 30-2 VF and 68 from the 10-2 VF) were clustered using the 'Hierarchical Ordered Partitioning And Collapsing Hybrid-Partitioning Around Medoids' algorithm. The stability of the identified clusters was evaluated using bootstrapping. RESULTS 65 sectors were identified in total: 38 sectors were located outside the 10-2 VF whereas 29 sectors were located inside the 10-2 VF (two sectors overlap in both grids). The mapping of many sectors appeared to follow the distribution of retinal nerve fiber bundles. The results of bootstrapping suggested clusters were stable whether they were outside or inside the 10-2 VF. CONCLUSION A considerable number of sectors were identified in the 10-2 VF area, despite the fact that clustering was carried out on all points in both the 30-2 VF and 10-2 VF simultaneously. These findings suggest that glaucomatous central VF deterioration cannot be picked up by the 30-2 test grid alone, because of poor spatial sampling; denser estimation of the central ten degrees, than offered by the 30-2 test grid alone, is needed. It may be beneficial to develop a new VF test grid that combines test points from 30-2 and 10-2 VFs--the results of this study could help to devise this test grid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sampling the Visual Field Based on Individual Retinal Nerve Fiber Layer Thickness Profile.

Purpose Current perimeters use fixed grid patterns. We test whether a grid based on an individual's retinal nerve fiber layer (RNFL) thickness profile would find more visual field (VF) defects. Methods We describe the defect-based method for choosing test locations. First, the 26 VF locations with the highest positive predictive value to detect glaucoma from the 24-2 pattern are chosen. An ad...

متن کامل

Variability in patients with glaucomatous visual field damage is reduced using size V stimuli.

PURPOSE To test the hypothesis that variability of conventional automated perimetry can be reduced using size V stimuli for patients with glaucomatous visual field damage. METHODS Ten patients with glaucoma and five age-matched control volunteers were tested with the Humphrey Field Analyzer program 24-2 or 30-2, after which the method of constant stimuli was used to measure frequency-of-seein...

متن کامل

Pattern Recognition Analysis Reveals Unique Contrast Sensitivity Isocontours Using Static Perimetry Thresholds Across the Visual Field

Purpose To determine the locus of test locations that exhibit statistically similar age-related decline in sensitivity to light increments and age-corrected contrast sensitivity isocontours (CSIs) across the central visual field (VF). We compared these CSIs with test point clusters used by the Glaucoma Hemifield Test (GHT). Methods Sixty healthy observers underwent testing on the Humphrey Fie...

متن کامل

Dose GRID increase the unwanted photoneutron dose to the patients in GRID therapy?

Introduction: GRID therapy is a treatment modality in which a high dose of radiation in a single fraction is given to the tumor. This technique previously was used to treat bulky tumors with orthovoltage beams. Recently, studies have been conducted to suggest that GRID therapy with megavoltage photons can be useful in palliative treatments. On the other hand, there has always ...

متن کامل

Modifying the Conventional Visual Field Test Pattern to Improve the Detection of Early Glaucomatous Defects in the Central 10°

PURPOSE To simulate modified versions of the 24-2 (6° grid) visual field (VF) test pattern by adding points from the 10-2 (2° grid) test pattern, and to assess their ability to detect early glaucomatous defects in the central 10°. METHODS One hundred forty-four eyes of 144 glaucoma patients and suspects with 24-2 mean deviations better than -6 dB were tested with 10-2 and 24-2 VFs. Based upon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014