An improved method for the quantification of left-to-right cardiac shunts.
نویسندگان
چکیده
We have investigated a technique for quantifying QP/QS in left-to-right cardiac shunts. In this method, the gamma variate, which is fitted to the first-pass portion of the lung curve, is used to generate a curve, which simulates the response of a normal lung curve with systemic recirculation. The difference between this curve and the observed lung curve is then used to calculate QP/QS. This method was evaluated on a set of simulated lung time-activity curves with precisely known QP/QS values on a group of 11 patients with no clinical suspicion of cardiac shunt and on a group of 30 patients referred for cardiac shunt studies. The QP/QS in each of these studies was determined by three individuals using both the Maltz-Treves method and the new method. This method yielded QP/QS values that were more accurate on the simulated lung data and had less interobserver variation on all the studies than those obtained from the Maltz-Treves method.
منابع مشابه
Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates
Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...
متن کاملNoninvasive detection and quantification of left-to-right shunts in children using oxygen-15 labeled carbon dioxide.
A method for the detection and quantification of left-to-right intracardiac shunts is described which utilizes a single breath inhalation of oxygen-15 labeled carbon dioxide (C15O2). The inhaled gas rapidly crosses the alveolar membrane and the oxygen-15 label is exchanged through the carbonate cycle to form oxygen-15 labeled water within the pulmonary capillary blood. Pulmonary indicator clear...
متن کاملQuantification of Partial Volume Effects in Salivary Glands SPECT Images after Radiation Therapy of Head and Neck Tumors
Introduction: Radical radiation therapy of head and neck cancers may injure the salivary glands and reduce their function. Single-photon emission computed tomography (SPECT) images maybe used to evaluate function post-therapy. However, accurate quantification is hindered by the partial volume effects (PVEs). The present study involved the introduction of a PVEs quantif...
متن کاملRight ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease
Introduction: In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...
متن کاملAn Evaluation of the Nitrous Oxide Method for the Quantification of Left - to - Right Shunts
Extensive clinical use has now been made of the nitrous oxide test for the detection and localization of left-to-right circulatory shunts. On theoretical grounds the magnitude of such a shunt should be related to the systemic and pulmonary arteriovenous differences in nitrous oxide content measured early in the period of inhalation. In order to determine the validity of the nitrous oxide method...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 32 9 شماره
صفحات -
تاریخ انتشار 1991