Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours.

نویسندگان

  • Y-M Kwon
  • S Glyn-Jones
  • D J Simpson
  • A Kamali
  • P McLardy-Smith
  • H S Gill
  • D W Murray
چکیده

The presence of pseudotumours, which are soft-tissue masses relating to the hip, after metal-on-metal hip resurfacing arthroplasty has been associated with elevated levels of metal ions in serum, suggesting that pseudotumours occur when there is increased wear. We aimed to quantify the wear in vivo of implants revised for pseudotumours (eight) and of a control group of implants (22) revised for other reasons of failure. We found that the implant group with pseudotumours had a significantly higher rate of median linear wear of the femoral component at 8.1 microm/year (2.75 to 25.4) than the 1.79 microm/year (0.82 to 4.15; p = 0.002) of the non-pseudotumour group. For the acetabular component a significantly higher rate of median linear wear of 7.36 microm/year (1.61 to 24.9) was observed in the pseudotumour group compared with 1.28 microm/year (0.81 to 3.33, p = 0.001) in the other group. Wear of the acetabular component in the pseudotumour group always involved the edge of the implant, indicating that edge-loading had occurred. Our findings are the first direct evidence that pseudotumour is associated with increased wear at the metal-on-metal articulation. Furthermore, edge-loading with the loss of fluid-film lubrication may be an important mechanism of generation of wear in patients with a pseudotumour.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo evaluation of edge-loading in metal-on-metal hip resurfacing patients with pseudotumours

OBJECTIVES Pseudotumours (abnormal peri-prosthetic soft-tissue reactions) following metal-on-metal hip resurfacing arthroplasty (MoMHRA) have been associated with elevated metal ion levels, suggesting that excessive wear may occur due to edge-loading of these MoM implants. This study aimed to quantify in vivo edge-loading in MoMHRA patients with and without pseudotumours during functional activ...

متن کامل

Implant failure in bilateral metal-on-metal hip resurfacing arthroplasties: a clinical and pathological study

Metal-on-metal hip resurfacing arthroplasties (MoMHRAs) have a high failure rate due to pseudotumour formation. It is not certain whether pseudotumours in bilateral MoMHRAs form on the basis of an adverse reaction to metal debris (ARMD) that is entirely due to a local innate and adaptive immune response to Cobalt-Chrome (Co-Cr) wear particles. To determine if there is a systemic component to AR...

متن کامل

Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear.

We sought to establish the incidence of joint failure secondary to adverse reaction to metal debris (ARMD) following metal-on-metal hip resurfacing in a large, three surgeon, multicentre study involving 4226 hips with a follow-up of 10 to 142 months. Three implants were studied: the Articular Surface Replacement; the Birmingham Hip Resurfacing; and the Conserve Plus. Retrieved implants underwen...

متن کامل

Pseudotumours associated with metal-on-metal hip resurfacing: 10-year Newcastle experience.

We report the incidence of pseudotumours in a single-surgeon consecutive series of 670 metal-on-metal hip resurfacings performed in the last ten years, with a minimum follow-up of one year. Two cases of pseudotumours have been found and are discussed in detail including metrology and wear analyses of the explanted components. The first was a painless, large synovial cyst in the thigh, secondary...

متن کامل

Asymmetrical hip loading correlates with metal ion levels in patients with metal-on-metal hip resurfacing during sit-to-stand.

The occurrence of pseudotumours following metal-on-metal hip resurfacing arthroplasty (MoMHRA) has been associated with high serum metal ion levels and consequently higher than normal bearing wear. Measuring ground reaction force is a simple method of collecting information on joint loading during a sit-to-stand (STS). We investigated vertical ground reaction force (VGRF) asymmetry during sit-t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 92 3  شماره 

صفحات  -