Experimental ASD closure using autologous cell-seeded interventional closure devices.

نویسندگان

  • Christian Jux
  • Harald Bertram
  • Peter Wohlsein
  • Michael Brügmann
  • Petra Wüboldt
  • Christoph Fink
  • Thomas Paul
  • Gerd Hausdorf
چکیده

OBJECTIVE Atrial septal defect (ASD) occluders are permanent implants in paediatric cardiology which serve as mechanical shields until complete overgrowth and incorporation of the occluding device by autologous tissue has occurred. Thereafter, the foreign body material making up the device is dispensable and bears potential long-term adverse effects. Rapid, firm and complete incorporation into the atrial septal wall should be a prerequisite for biodegradable devices. In this study, the feasibility of using autologous cell-seeded devices was investigated by (a) testing the influence of a collagen coating on cellular stress resistance in vitro and (b) comparing the short-term effects between cell-seeded, collagen-coated and acellular ASD occluders in vivo. METHODS Native and collagen-coated Dacon fabrics and Starflex-devices were pre-seeded with autologous fibroblasts (skin biopsy) and evaluated using various mechanical stress tests. In a sheep model interventionally created ASDs were closed using either autologous pre-seeded or conventional (acellular) Starflex-devices. RESULTS ASD closure devices were successfully pre-seeded with autologous cells. The incubation period needed, the cellular density achieved and the mechanical stability of the cytolayer after mechanical stressing (implantation) were improved by applying a collagen matrix on the fabric. Compared to the thin layer of ingrown tissue seen on conventional occluders after 30 days in vivo, a thicker layer of organising, newly formed granulation tissue on pre-seeded collagen-coated devices embedded not only the Dacron fabric, but also completely covered the spring arms of the device underneath a layer of neo-endothelium. CONCLUSION Autologous cell pre-seeding of interventional closure devices is feasible since the cells survive the mechanical stress encountered during implantation. Rapid, firm and complete ingrowth of occluder devices into a thicker layer of young fibrous granulation tissue can be achieved, but an increased thrombogenicity currently limits the in vivo application.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy and safety of transcatheter closure in adults with large or small atrial septal defects

BACKGROUND In most patients with secundum atrial septal defects (ASD), transcatheter closure is the preferred treatment strategy, but whether device size affects clinical outcomes is unknown. We sought to study the efficacy and safety of large closure devices compared to the use of smaller devices. METHODS Using a single-center, prospective registry of adult patients undergoing transcatheter ...

متن کامل

Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty

Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...

متن کامل

The use of echocardiography in pediatric interventional cardiac catheterization procedures.

The last decade saw a dramatic change in the management of congenital heart defects. The introduction and development in echocardiography and Doppler modalities enable definitive diagnosis of congenital lesions without cardiac catheterization. At the same time, new therapeutic procedures for congenital defects using the catheter as a channel for different procedures were developed. These therap...

متن کامل

Closure of a Recurrent Bronchopleural Fistula Using a Matrix Seeded With Patient-Derived Mesenchymal Stem Cells

: Management of recurrent bronchopleural fistula (BPF) after pneumonectomy remains a challenge. Although a variety of devices and techniques have been described, definitive management usually involves closure of the fistula tract through surgical intervention. Standard surgical approaches for BPF incur significant morbidity and mortality and are not reliably or uniformly successful. We describe...

متن کامل

Is it worth closing the atrial septal defect in patients with insignificant shunt?

INTRODUCTION Closure of the atrial septal defect in patients with insignificant shunt is controversial. AIM To evaluate the outcomes of transcatheter closure of atrial septal defect (ASD) in symptomatic patients with borderline shunt. MATERIAL AND METHODS One hundred and sixty patients (120 female, 40 male) with a mean age of 30.1 ±16.2 (20-52) years with a small ASD who underwent transcath...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Cardiovascular research

دوره 53 1  شماره 

صفحات  -

تاریخ انتشار 2002