Comparison of improved Aura Tropospheric Emission Spectrometer CO2 with HIPPO and SGP aircraft profile measurements
نویسندگان
چکیده
Thermal infrared radiances from the Tropospheric Emission Spectrometer (TES) between 10 and 15 μm contain significant carbon dioxide (CO2) information, however the CO2 signal must be separated from radiative interference from temperature, surface and cloud parameters, water, and other trace gases. Validation requires data sources spanning the range of TES CO2 sensitivity, which is approximately 2.5 to 12 km with peak sensitivity at about 5 km and the range of TES observations in latitude (40 S to 40 N) and time (2005–2011). We therefore characterize Tropospheric Emission Spectrometer (TES) CO2 version 5 biases and errors through comparisons to ocean and land-based aircraft profiles and to the CarbonTracker assimilation system. We compare to ocean profiles from the first three Hiaper Pole-to-Pole Observations (HIPPO) campaigns between 40 S and 40 N with measurements between the surface and 14 km and find that TES CO2 estimates capture the seasonal and latitudinal gradients observed by HIPPO CO2 measurements. Actual errors range from 0.8–1.8 ppm, depending on the campaign and pressure level, and are approximately 1.6–2 times larger than the predicted errors. The bias of TES versus HIPPO is within 1 ppm for all pressures and datasets; however, several of the sub-tropical TES CO2 estimates are lower than expected based on the calculated errors. Comparisons to land aircraft profiles from the United States Souther Great Plains (SGP) Atmospheric Radiation Measurement (ARM) between 2005 and 2011 measured from the surface to 5 km to TES CO2 show good agreement with an overall bias of −0.3 ppm to 0.1 ppm and standard deviations of 0.8 to 1.0 ppm at different pressure levels. Extending the SGP aircraft profiles above 5 km using AIRS or CONTRAIL measurements improves comparisons with TES. Comparisons to CarbonTracker (version CT2011) show a persistent spatially dependent bias pattern and comparisons to SGP show a time-dependent bias of −0.2 ppm yr−1. We also find that the predicted sensitivity of the TES CO2 estimates is too high, which results from using a multi-step retrieval for CO2 and temperature. We find that the averaging kernel in the TES product corrected by a pressure-dependent factor accurately reflects the sensitivity of the TES CO2 product. Published by Copernicus Publications on behalf of the European Geosciences Union. 3206 S. S. Kulawik et al.: Comparison of improved Aura Tropospheric Emission Spectrometer CO2
منابع مشابه
Characterization of Aura TES carbonyl sulfide retrievals over ocean
We present a description of the NASA Aura Tropospheric Emission Spectrometer (TES) carbonyl sulfide (OCS) retrieval algorithm for oceanic observations, along with evaluation of the biases and uncertainties using aircraft profiles from the HIPPO (HIAPER Pole-to-Pole Observations) campaign and data from the NOAA Mauna Loa site. In general, the OCS retrievals (1) have less than 1.0 degree of freed...
متن کاملProfiling tropospheric CO2 using Aura TES and TCCON instruments
Monitoring the global distribution and long-term variations of CO2 sources and sinks is required for characterizing the global carbon budget. Total column measurements are useful for estimating regional-scale fluxes; however, model transport remains a significant error source, particularly for quantifying local sources and sinks. To improve the capability of estimating regional fluxes, we estim...
متن کاملMeasurements of SO[2] profiles in volcanic plumes from the NASA Tropospheric Emission Spectrometer (TES)
[1] Satellite measurements are now recognized as a key element for the early detection and characterization of volcanic eruptions, in particular in the context of aircraft routing. A common tracer of volcanic plumes is sulfur dioxide (SO2), which so far has been measured by ultraviolet-visible (UV-vis) instruments and multispectral infrared (IR) sounders. Here we report the first SO2 vertical p...
متن کاملValidation of Tropospheric Emission Spectrometer ozone profiles with aircraft observations during the Intercontinental Chemical Transport Experiment–B
[1] The Tropospheric Emission Spectrometer (TES) is an infrared instrument that was launched on board NASA’s Aura satellite in 2004. TES is the first instrument to provide vertical information on tropospheric ozone while simultaneously measuring CO on a global basis. Before they may be used for scientific study, TES profiles must first be validated to determine if there are any systematic biase...
متن کاملValidation of Tropospheric Emission Spectrometer (TES) measurements of the total, stratospheric, and tropospheric column abundance of ozone
[1] The Tropospheric Emission Spectrometer (TES) is an infrared, high-resolution Fourier transform spectrometer which was launched onboard NASA’s Aura satellite in 2004 and is providing global, vertically resolved measurements of ozone in the troposphere. TES version 2 (V002) data profiles have been validated in the troposphere and lower stratosphere by way of comparison to ozonesondes and airc...
متن کامل