QT interval variability and spontaneous ventricular tachycardia or fibrillation in the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II patients.

نویسندگان

  • Mark C Haigney
  • Wojciech Zareba
  • Philip J Gentlesk
  • Robert E Goldstein
  • Michael Illovsky
  • Scott McNitt
  • Mark L Andrews
  • Arthur J Moss
چکیده

OBJECTIVES This study aimed to determine whether increased QT interval variability is associated with an increased risk for ventricular tachycardia (VT) or ventricular fibrillation (VF), documented by interrogation of the implantable cardioverter-defibrillator (ICD), in patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II. BACKGROUND Unstable repolarization has been proposed as a risk factor for re-entrant arrhythmias, but confirmatory data from clinical trials are lacking. METHODS The QT variability was assessed in 10-min, resting high-resolution electrocardiogram recordings at study entry using a semiautomated algorithm that measured beat-to-beat QT duration in 817 MADIT II patients. The incidence of VT/VF requiring device therapy was determined by ICD interrogation. RESULTS Median normalized QT variability (QTVN) was 0.179 and 0.125, respectively, in patients with VT/VF versus those without VT/VF (p = 0.001); QTVI (QTVN adjusted for heart rate variance) also was significantly (p < 0.05) higher in VT/VF patients than in those without VT/VF. Either QTVN or QTVI was linked with a significantly higher probability of VT/VF: two-year risk of VT/VF from Kaplan-Meier curves was 40% in highest quartile versus 21% in lower quartiles for QTVN, and 37% versus 22% for QTVI (p < 0.05 for each). In multivariate Cox regression models adjusting for clinical covariates (race, New York Heart Association functional class, time after myocardial infarction), top-quartile QTVI and QTVN were independently associated with VT/VF (hazard ratio for QTVN 2.18, 95%confidence interval [CI] 1.34 to 3.55, p = 0.002; hazard ratio for QTVI 1.80, 95% CI 1.09 to 2.95, p = 0.021). CONCLUSIONS In postinfarction patients with severe left ventricular dysfunction, increased QT variability, a marker of repolarization lability, is associated with an increased risk for VT/VF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictive value of ventricular arrhythmia inducibility for subsequent ventricular tachycardia or ventricular fibrillation in Multicenter Automatic Defibrillator Implantation Trial (MADIT) II patients.

UNLABELLED In the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II, implantable cardioverter-defibrillator (ICD)-randomized patients underwent electrophysiologic testing. Both inducible and noninducible patients received an ICD. We correlated inducibility with the occurrence of subsequent ventricular tachycardia (VT) or ventricular fibrillation (VF). Intracardiac ICD electrogra...

متن کامل

Repolarization variability in the risk stratification of MADIT II patients.

AIMS QT variability has been reported to be associated with ventricular arrhythmias and sudden cardiac death. There is limited data regarding variability in T-wave morphology and its prognostic value. In this study, we present a novel approach for the measurement of T-wave variability (TWV) reflecting changes in T-wave morphology, and we investigate the prognostic significance of Holter-derived...

متن کامل

Mortality and predictors of appropriate implantable cardioverter defibrillator therapy in Japanese patients with Multicenter Automatic Defibrillator Implantation Trial II criteria

BACKGROUND Data regarding long-term mortality and factors influencing appropriate therapies in Japanese patients with implantable cardioverter defibrillators (ICD), who satisfy the Multicenter Automatic Defibrillator Implantation Trial II (MADIT II) criteria for primary prevention, remain scarce. METHODS A total of 118 consecutive patients who underwent ICD implantation without any prior vent...

متن کامل

Reverse remodeling and the risk of ventricular tachyarrhythmias in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy).

OBJECTIVES We aimed to evaluate the relationship between echocardiographic response to cardiac resynchronization therapy (CRT) and the risk of subsequent ventricular tachyarrhythmias (VTAs). BACKGROUND Current data regarding the effect of CRT on the risk of VTA are limited and conflicting. METHODS The risk of a first appropriate implantable cardioverter-defibrillator (ICD) therapy for VTA (...

متن کامل

The prediction of ICD therapy in multicenter automatic defibrillator implantation trial (MADIT) II like patients: a retrospective analysis

OBJECTIVES MADIT II like patients have not been compared to patients without an electrophysiological study, patients in whom ventricular tachycardia or fibrillation were induced in an electrophysiological study (EPS) and patients without an inducibility in EPS in one study. BACKGROUND The multicenter automatic defibrillator implantation trial (MADIT) II showed a benefit of ICD implantation in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 44 7  شماره 

صفحات  -

تاریخ انتشار 2004