Flow cytometric method for enumeration and classification of reactive immature granulocyte populations.
نویسندگان
چکیده
We developed a flow cytometric method for the enumeration and classification of nonmalignant immature granulocytes (IG). In this study, IG are defined as most immature (IG stage 1: promyelocytes and myelocytes) and as more mature (IG stage 2: metamyelocytes). Blood specimens from 46 patients with documented infectious or inflammatory disease and known presence of IG (by routine manual microscopy) were analyzed. For a reference manual differential count, we used a 400 white blood cell (WBC) differential and separated granulocytes into promyelocytes and myelocytes combined, metamyelocytes, and included band cells in the mature, segmented neutrophil population. The flow cytometric method is based on three-color staining of whole, anticoagulated blood with CD45-PerCP, CD16-FITC, and CD11b-PE-labeled monoclonal antibodies and a three-step gating procedure. The flow cytometric results were confirmed by cell sorting and microscopic evaluation of the sorted cells. A total of 10,000 events, excluding debris, were recorded per specimen and IG stage 1 (CD16-/CD11b-), IG stage 2 (CD16-/CD11b+), and mature neutrophils (CD16+/CD11b+) were categorized. Regression and correlation between flow cytometric IG and the manual differential showed y = 1.34x + 0.95, r(2) = 0.86 for IG stages 1 and 2 combined versus promyelocytes, myelocytes, and metamyelocytes. For IG stage 1 versus microscopic counts of promyelocytes and myelocytes, the results were y = 1.53x + 1.24, r(2) = 0.76; for IG stage 2 versus manual metamyelocyte count, y = 0.77x + 0.21, r(2) = 0.58. Reproducibility of the flow cytometric method showed a coefficient of variation (CV) of 6.8% for all IG combined compared with a CV of 50.2% for manual differential IG count (based on a routine 100 WBC count). Samples were found stable at least 12 h at 25 degrees C and at least 48 h at 4 degrees C for flow cytometry. After staining and lysing, the sample was stable for at least 120 min at room temperature. We analyzed samples from patients with myelodysplastic and myeloproliferative disease separately. We found that CD16- mature neutrophils falsely elevated the flow cytometric IG count. Similar results were obtained in blood from patients treated with granulocyte-colony stimulating factor (G-CSF). Although this restricts the use of the method somewhat, we believe that this flow cytometric method is useful for enumerating reactive IG, as well as for evaluating automated methods for IG identification by hematology analyzers.
منابع مشابه
Automated enumeration of immature granulocytes.
The performance characteristics of the XE-2100 (Sysmex, Kobe, Japan) automated immature granulocyte (IG) count were studied. The automated IG count was compared with the manual morphology count and with a proposed reference flow cytometric count. The comparison data were analyzed by both least-squares and Passing-Bablok regression analysis. Long-term imprecision using preserved blood quality co...
متن کاملFlow cytometric characterization of freshwater crayfish hemocytes for the examination of physiological status in wild and captive animals.
Enumeration of invertebrate hemocytes is a potentially powerful tool for the determination of physiological effects of extrinsic stressors, such as hypoxia, disease, and toxicant exposure. A detailed flow cytometric method of broad application was developed for the objective characterization and enumeration of the hemocytes of New Zealand freshwater crayfish Paranephrops planifrons for the purp...
متن کاملNew quantitative parameters on a recently introduced automated blood cell counter--the XE 2100.
The XE 2100 (Sysmex Corporation) is a cell counter that furthers the technology of fluorescent flow cytometry developed from the earlier range of Sysmex analysers. The new diagnostic features are a nucleated red cell count (NRBC), the ability to measure platelets by impedance as well as an 'optical' platelet count using a fluorescence dye and an immature granulocyte (IG) count. The NRBC count w...
متن کاملA Method for Identification and Analysis of Non-Overlapping Myeloid Immunophenotypes in Humans
The development of flow cytometric biomarkers in human studies and clinical trials has been slowed by inconsistent sample processing, use of cell surface markers, and reporting of immunophenotypes. Additionally, the function(s) of distinct cell types as biomarkers cannot be accurately defined without the proper identification of homogeneous populations. As such, we developed a method for the id...
متن کاملDetection of defective granulocyte function with flow cytometry in newborn infants.
Reactive oxygen species (ROS) production by phagocytic leukocytes is a critical factor in immunity against microorganisms. Human neonates are susceptible to overwhelming infections, for which abnormal granulocyte function may play an important role. In this study, we aimed to identify a convenient and quantitative method to measure ROS production by human granulocytes after cellular activation....