Evaluation of the risk of a stripping perforation with Gates-Glidden drills: serial versus crown-down sequences.

نویسندگان

  • Tauby Coutinho-Filho
  • Gustavo De-Deus
  • Eduardo Diogo Gurgel-Filho
  • Ana Carolina Rocha-Lima
  • Katia Regina Cervantes Dias
  • Carlos Augusto Barbosa
چکیده

The aim of this study was to evaluate the remaining dentine/cementum thickness using Gates-Glidden burs in serial and crown-down sequences and to observe which of the two sequences is the safest for preparing mesial roots of molars. Thirty-six left and right human mandibular first molars were selected. Standard access cavities were made and initially explored with Flexofiles sizes 10 and 15 until the tip was visible at the apex. The teeth were embedded in a muffle specially developed for this study using a PVC tube with two parallel metal rods in its lid. Each tooth-block was sectioned 3 mm apically to the furcation using a low-speed saw with a diamond disc. The tooth-block was examined under a microscope and an initial image was captured by a digital video system with 8 X and 12 X magnifications. Finally, the tooth-blocks were reassembled in the muffle so that the canals could be instrumented. After instrumentation the area of each mesial canal as well as the smallest distance to the root furcation were measured again. The mesio-buccal canals (crown-down order) and the mesio-lingual canals (serial sequence) presented an average area of 0.46 +/- 0.16 mm(2) and 0.88 +/- 0.27 mm(2) (P < 0.01), respectively. The mean values of the smallest distance to the furcation for the mesio-buccal and mesio-lingual canals were 0.66 +/- 0.19 mm and 0.39 +/- 0.13 mm (P < 0.01), respectively. The remaining dentine/cementum thickness using Gates-Glidden burs was greater in the crown-down sequence than in the serial sequence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Effect of ProTaper and Gates-Glidden Drills On the Remaining Root Dentin Thickness at the Coronal Region of the Root

Background and Aim: The purpose of this study was to evaluate residual dentin thickness of the root and the area of the canal lumen in the coronal region of the mesiobuccal and mesiolingual canals of the lower first molars after canal preparation with the common method of using hand files and Gates Glidden drills or ProTaper rotary files, by Spiral Ct-Scan. Materials and Methods: In this exp...

متن کامل

مقایسه تأثیر آماده‌سازی کانال دندان به روش استپ بک با استفاده از فایل‌های دستی و گیتس گلیدن، با سیستم روتاری پروتیپر در مقاومت ریشه به شکستگی عمودی

Introduction: Cleaning and shaping of the root canal system with an efficient and safe technique are the major goals of root canal treatment. The aim of this study was to compare the conventional root canal preparation technique by hand instruments and Gates Glidden drills with ProTaper Universal Rotary system on the root susceptibility to vertical fracture. Methods: Thirty extracted human man...

متن کامل

CBCT Assessment of Root Dentine Removal by Gates-Glidden Drills and Two Engine-Driven Root Preparation Systems

INTRODUCTION The aim of this study was to compare the dentine removing efficacy of Gates-Glidden drills with hand files, ProTaper and OneShape single-instrument system using cone-beam computed tomography (CBCT). METHODS AND MATERIALS A total of 39 extracted bifurcated maxillary first premolars were divided into 3 groups (n=13) and were prepared using either Gates-Glidden drills and hand instr...

متن کامل

بررسی رادیوگرافیکی تغییرات ابعادی کانال و حوادث در دندان‌‌های مولر متعاقب استفاده از روش‌های اینسترومنتیشن دستی و چرخشی

  Background: Stainless steel instruments have long used as conventional instruments applied in root canal therapy procedures. Being difficult the canal preparation by these instruments, a new generation of nickel-titanium instruments have introduced. The aim of this study was to compare the manual Ni-Ti instruments with the Flex Master® Ni-Ti rotary system in canal preparation.   Materials & M...

متن کامل

Comparison of the effects of TripleGates and Gates-Glidden burs on cervical dentin thickness and root canal area by using cone beam computed tomography

UNLABELLED The search for new instruments to promote an appropriate cervical preparation has led to the development of new rotary instruments such as TripleGates. However, to the best of the authors' knowledge, there is no study evaluating TripleGates effect on the "risk zone" of mandibular molars. OBJECTIVES The aim of this study was to evaluate the effects of a crown-down sequence of Gates-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian oral research

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 2008