Reference left atrial dimensions and volumes by steady state free precession cardiovascular magnetic resonance

نویسندگان

  • Alicia M Maceira
  • Juan Cosín-Sales
  • Michael Roughton
  • Sanjay K Prasad
  • Dudley J Pennell
چکیده

BACKGROUND Left atrial (LA) size is related to cardiovascular morbidity and mortality. Cardiovascular magnetic resonance (CMR) provides high quality images of the left atrium with high temporal resolution steady state free precession (SSFP) cine sequences. We used SSFP cines to define normal ranges for LA volumes and dimensions relative to gender, age and body surface area (BSA), and examine the relative value of 2D atrial imaging techniques in patients.For definition of normal ranges of LA volume we studied 120 healthy subjects after careful exclusion of cardiovascular abnormality (60 men, 60 women; 20 subjects per age decile from 20 to 80 years). Data were generated from 3-dimensional modeling, including tracking of the atrioventricular ring motion and time-volume curves analysis. For definition of the best 2D images-derived predictors of LA enlargement, we studied 120 patients (60 men, 60 women; age range 20 to 80 years) with a clinical indication for CMR. RESULTS In the healthy subjects, age was associated with LA 4-chamber transverse and 3-chamber anteroposterior diameters, but not with LA volume. Gender was an independent predictor of most absolute LA dimensions and volume, but following normalization to BSA, some associations became non-significant. CMR normal ranges were modeled and are tabled for clinical use with normalization, where appropriate, for BSA and gender and display of parameter variation with age. The best 2D predictors of LA volume were the 2-chamber area and 3-chamber area (both r = 0.90, p < 0.001). CONCLUSIONS These CMR data show that LA dimensions and volume in healthy, individuals vary significantly by BSA, with lesser effects of age and gender.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

VENTRICULAR FUNCTION Normal human left and right ventricular and left atrial dimensions using steady state free precession magnetic resonance imaging

Purpose. The aim of this project was to establish a database of left and right ventricular and left atrial dimensions in healthy volunteers using steady-state free precession cardiac magnetic resonance imaging, the clinical technique of choice, across a wide age range. Methods. 108 healthy volunteers (63 male, 45 female) underwent cardiac magnetic resonance imaging using steady-state free prece...

متن کامل

Reference right atrial function determined by steady-state free precession cardiovascular magnetic resonance.

BACKGROUND There is agreement that measurements of atrial volumes and ejection fraction (EF) are superior to atrial diameters for accurate determination of atrial size, follow up studies and prognosis. However, reference values for right atrial volumes and EF for cardiovascular magnetic resonance (CMR) have not been established but are crucial to identify patients with impaired right atrial fun...

متن کامل

Reference right atrial dimensions and volume estimation by steady state free precession cardiovascular magnetic resonance

BACKGROUND Cardiovascular magnetic resonance (CMR) steady state free precession (SSFP) cine sequences with high temporal resolution and improved post-processing can accurately measure RA dimensions. We used this technique to define ranges for normal RA volumes and dimensions normalized, when necessary, to the influence of gender, body surface area (BSA) and age, and also to define the best 2D i...

متن کامل

Quantification of the relationship between two cardiac magnetic resonance techniques: fast gradient echo and steady-state free precession for determination of left atrial volumes

Background Steady-state free precession (SSFP) results in larger volumes and lower ejection fraction for the left ventricle compared to fast gradient echo (fGRE) imaging. Similar comparisons for the left atrium (LA) are not available and may be relevant for 3T imaging and historical comparison to prior imaging datasets. As opposed to LV imaging, volumes in the LA are more commonly derived using...

متن کامل

Improved accuracy of quantitative assessment of left ventricular volume and ejection fraction by geometric models with steady-state free precession.

The purpose of this study was to determine whether steady-state free precession (SSFP) could improve accuracy of geometric models for evaluation of left ventricular (LV) function in comparison to turbo gradient echo (TGrE) and thereby reduce the acquisition and post-processing times, which are commonly long by use of the Simpson's Rule. In 25 subjects, cine loops of the complete heart in short ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2010