Biometry of phakic intraocular lens using Scheimpflug photography.

نویسندگان

  • Joris E Coppens
  • Thomas J T P van den Berg
  • Camille J Budo
چکیده

PURPOSE To examine lateral and axial positioning of phakic intraocular lenses (IOLs) with iris fixation in the anterior chamber and to examine short-term stability of the IOL position. SETTING The Netherlands Opthalmic Research Institute, Amsterdam, the Netherlands. METHODS Thirty patients participated in the study. Thirty-one eyes were implanted with the 204 type myopia IOL, 14 eyes with the 206 myopia IOL, and 8 eyes with the 203 hyperopia IOL. Scheimpflug slitlamp photographs were made through the optical axis along 4 meridians of the eyes. Ray tracing was used to obtain the lateral and axial position of the IOLs. RESULTS Centration of the IOL with respect to the pupil's center and the tilt angle of the IOL with respect to the optical axis of the eye were measured. Standard deviation of decentration was 0.21 mm vertically and 0.16 mm horizontally. Standard deviation of tilt was 1.30 degrees vertically and 0.90 degrees horizontally. Tilt and decentration are proportional to each other. Vaulting, the distance between the crystalline lens and the IOL, was constant over a period of 24 months, ranging from 0.2 to 0.8 mm, depending primarily on the radius of curvature of the crystalline lens. A geometric model for this dependence was formulated. CONCLUSION Phakic IOLs with iris fixation can be positioned in the eye with submillimeter precision. Axial position of iris-fixated phakic IOLs over time is excellent. Axial position and vaulting can be predicted when the radius of curvature of the crystalline lens is known. The IOL behaves as if mounted slightly above a sphere-the anterior surface of the crystalline lens.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Iris-fixated phakic intraocular lens implantation for correction of high myopia in microspherophakia.

We report the refractive correction of high myopia in a 23-year-old patient with idiopathic microspherophakia using iris-fixated phakic intraocular lenses (pIOLs) (Verisyse/Artisan). Four years after bilateral implantation, the uncorrected distance visual acuity was 20/25 with a correction of 20/20(-1) in both eyes. No intraoperative or postoperative complications occurred. Iris-fixated pIOLs a...

متن کامل

Position of rigid and foldable iris-fixated myopic phakic intraocular lenses evaluated by Scheimpflug photography.

PURPOSE To evaluate the postoperative intraocular positional stability of 1 rigid poly(methyl methacrylate) (PMMA) phakic intraocular lens (pIOL) model and 2 foldable polysilicone-PMMA iris-fixated pIOL models. SETTING Department of Ophthalmology, Johann Wolfgang Goethe-University Frankfurt am Main, Germany. METHODS One of 3 iris-fixated pIOL models (Artisan, Artiflex I, and Artiflex II, Op...

متن کامل

Behaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse) during accommodation: an optical coherence biometry study.

PURPOSE To evaluate variations in the position of the phakic iris claw lens (Artisan, Verisyse) and the natural crystalline lens during the accommodation process. METHODS We measured changes in position of the iris claw lens and the crystalline lens during the accommodation using optical coherence biometry (AC Master/Carl Zeiss Meditec, Germany) in 17 patients (28 eyes) with a phakic iris cla...

متن کامل

Steeper Iris Conicity Is Related to a Shallower Anterior Chamber: The Gutenberg Health Study

PURPOSE To report the distribution of iris conicity (steepness of the iris cone), investigate associated factors, and test whether pseudophakia allows the iris to sink back. METHODS A population-based cross-sectional study was carried out. Ophthalmological examination including objective refraction, biometry, noncontact tonometry, and Scheimpflug imaging (Pentacam®, Oculus) was performed incl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 31 10  شماره 

صفحات  -

تاریخ انتشار 2005