Testing of Cryogenic Photomultiplier Tubes for the MicroBooNE Experiment

نویسندگان

  • T. Briese
  • L. Bugel
  • J. M. Conrad
  • M. Fournier
  • C. Ignarra
  • B. J. P. Jones
  • T. Katori
  • R. Navarrete
  • P. Nienaber
  • B. Musolf
  • A. Prakash
  • E. Shockley
  • T. Smidt
  • K. Swanson
  • M. Toups
چکیده

The MicroBooNE detector, to be located on axis in the Booster Neutrino Beamline (BNB) at the Fermi National Accelerator Laboratory (Fermilab), consists of two main components: a large liquid argon time projection chamber (LArTPC), and a light collection system. Thirty 8inch diameter Hamamatsu R5912-02mod cryogenic photomultiplier tubes (PMTs) will detect the scintillation light generated in the liquid argon (LAr). This article first describes the MicroBooNE PMT performance test procedures, including how the light collection system functions in the detector, and the design of the PMT base. The design of the cryogenic test stand is then discussed, and finally the results of the cryogenic tests are reported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Summer 2013 REU Research Summary : MicroBooNE

This paper is a final write-up of my work at Columbia University/Nevis Labs as part of the NSF-sponsered REU program. The paper begins with a discussion of the physics and scientific goals of MicroBooNE. It then moves on to a summary of my contributions to the project. These include commissioning of the TPC readout equipment, calibration of the PMT readout system, and construction of an interac...

متن کامل

Comparative assessment of the accuracy of maximum likelihood and correlated signal enhancement algorithm positioning methods in gamma camera with large square photomultiplier tubes

Introduction: The gamma cameras, based on scintillation crystal followed by an array of photomultiplier tubes (PMTs), play a crucial role in nuclear medicine. The use of square PMTs provides the minimum dead zones in the camera. The camera with square PMTs also reduces the number of PMTs relative to the detection area. Introduction of a positioning algorithm to improve the spat...

متن کامل

The photomultiplier tube testing facility for the Borexino experiment at LNGS

A facility to test the photomultiplier tubes (PMTs) for the solar neutrino detector Borexino was built at the Gran Sasso laboratory. Using the facility 2200 PMTs with optimal characteristics were selected from the 2350 delivered from the manufacturer. The details of the hardware used are presented. r 2004 Published by Elsevier B.V.

متن کامل

Testing of Hamamatsu R5900-00-M64 Multi-Pixel PMTs for MINOS

The MINOS long baseline neutrino oscillation experiment is comprised of three calorimeters, a Near Detector at FNAL, a Far Detector at the Soudan mine in northern Minnesota, and a Calibration Detector in a test beam at CERN. The light produced in the interactions of neutrinos in the Near Detector at FNAL will be routed by optical fibres onto the pixels of Hamamatsu R5900-00-M64 multi-anode phot...

متن کامل

The Waveform Digitiser of the Double Chooz Experiment: Performance and Quantisation Effects on PhotoMultiplier Tube Signals

We present the waveform digitiser used in the Double Chooz experiment. We describe the hardware and the custom-built firmware specifically developed for the experiment. The performance of the device is tested with regards to digitising low light level signals from photomultiplier tubes and measuring pulse charge. This highlights the role of quantisation effects and leads to some general recomme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013