The calculation of total dose using SPENVIS
نویسنده
چکیده
The potential radiation dose for the Solar-B EIS CCDs was discussed in reference [1], and the potential effect of that radiation dose was discussed in reference [2]. Whilst the effect of ionising radiation on CCD areas such as flat band voltage shifts was not a cause for concern (although the transient effects on image quality may be) there was a potential problem with the effect of Non-Ionising Radiation damage on the CCD’s Charge Transfer Inefficiency (CTI). Consequently, it was recommended that an operating temperature of around -80°C or so may be necessary to ensure adequate CTI. However, subsequent thermal studies have shown that such a low temperature may be difficult to reach.
منابع مشابه
Patient dose calculation software in nuclear medicine [Persian]
Introduction: Radioactive materials deliver internal radiation dose to patients in nuclear medicine. Manual internal radiation dose assessment is a complicated method. Introduction of a simple dose calculation software is the main goal of the present study. Methods: Using the best current data in internal dose calculation (S-Factors) recommended by ICRP and by cons...
متن کاملCalculation of total dose and dose equivalent distribution in the treatment of lung cancer using MR-guided carbon therapy
Nowadays, in order to improve the accuracy of treatment in radiation therapy, there are many attempts to use magnetic resonance imaging (MRI) due to the advantages of excellent soft tissue contrast and ultra-fast pulse sequences. On the other hand, carbon-ion radiation therapy is developing rapidly due to the benefits of greater relative biological effectiveness (RBE) and the application in the...
متن کاملCalculation and evaluation of the vital head organs dose during Neutron Therapy in Tehran Research Reactor using Zubal phantom
In the recent years some studies has been done to consider the capability of Tehran Research Reactor for Boron neutron capture therapy (BNCT). The purpose of this study is to evaluate the sensitive organs dose during the treatment of patient with deep brain tumor by TRR. The calculation has been carried out using the Monte Carlo code MCNPX for ZUBAL head and neck phantom. The method was tested ...
متن کاملAbsorbed Dose Calculation In Irregular Blocked Radiation Fields: Evaluation of Clarkson’s Sector Integration Method for Radiation Fields Commonly Used in Conventional Radiotherapy
Introduction: Irregular/blocked fields are routinely used in radiotherapy. The doses of these fields are usually calculated by means of equivalent square method that is inherently prone to uncertainty. On the other hand, Clarkson’s sector integration method is a dose calculation method which offers far better accuracy in dose calculation of irregular fields. The Scatter Air Ratio (SAR) of an in...
متن کاملCalculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography
Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...
متن کامل