Stabilized hot electron bolometer heterodyne receiver at 2.5THz
نویسندگان
چکیده
Related Articles Afterpulsing and instability in superconducting nanowire avalanche photodetectors Appl. Phys. Lett. 100, 112601 (2012) Plasmonic detector/spectrometer of subterahertz radiation based on two-dimensional electron system with embedded defect Appl. Phys. Lett. 100, 082102 (2012) Modeling and analysis of intraband absorption in quantum-dot-in-well mid-infrared photodetectors J. Appl. Phys. 111, 033713 (2012) InAs/InAsSb strain balanced superlattices for optical detectors: Material properties and energy band simulations J. Appl. Phys. 111, 034507 (2012) Effect of overgrowth temperature on the mid-infrared response of Ge/Si(001) quantum dots Appl. Phys. Lett. 100, 053507 (2012)
منابع مشابه
An All Solid-State Superconducting Heterodyne Receiver at Terahertz Frequencies
A superconducting hot-electron bolometer mixer receiver operating from 1 to 1.26 THz has been developed. This heterodyne receiver employs two solid-state local oscillators each consisting of a Gunn oscillator followed by two stages of varactor frequency multiplication. The measured receiver noise temperature is 1350K at 1.035 THz and 2700K at 1.26 THz. This receiver demonstrates that tunable so...
متن کاملApplication of Superconducting Hot-Electron Bolometer Mixers for Terahertz-Band Astronomy
Recently, a next-generation heterodyne mixer detector— a hot electron bolometer (HEB) mixer employing a superconducting microbridge—has gradually opened up terahertz-band astronomy. The surrounding state-of-the-art technologies including fabrication processes, 4 K cryostats, cryogenic low-noise amplifiers, local oscillator sources, micromachining techniques, and spectrometers, as well as the HE...
متن کاملLarge bandwidth and low noise in a diffusion-cooled hot-electron bolometer mixer
Heterodyne measurements have been made at 533 GHz using a novel superconducting hot-electron bolometer in a waveguide mixer. The bolometer is a 0.3 mm long niobium microbridge with a superconducting transition temperature of 5 K. The short length ensures that electron diffusion dominates over electron-phonon interactions as the electron cooling mechanism, which should allow heterodyne detection...
متن کاملFull characterization and analysis of a terahertz heterodyne receiver based on a NbN hot electron bolometer
We present a complete experimental characterization of a quasioptical twin-slot antenna coupled small area 1.0 0.15 m2 NbN hot electron bolometer HEB mixer compatible with currently available solid state tunable local oscillator LO sources. The required LO power absorbed in the HEB is analyzed in detail and equals only 25 nW. Due to the small HEB volume and wide antenna bandwidth, an unwanted d...
متن کاملA 4.7THz heterodyne receiver for a balloon borne telescope
We report on the performance of a high sensitivity 4.7 THz heterodyne receiver based on a NbN hot electron bolometer mixer and a quantum cascade laser (QCL) as local oscillator. The receiver is developed to observe the astronomically important neutral atomic oxygen [OI] line at 4.7448 THz on a balloon based telescope. The single-line frequency control and improved beam pattern of QCL have taken...