An interlaboratory study of a candidate reference method for platelet counting.
نویسندگان
چکیده
A multinational interlaboratory task force explored the important variables of platelet reference counting and developed a candidate flow cytometric reference method based on the RBC/platelet ratio. A multicenter comparison was performed to determine whether the method met the necessary criteria and was precise enough to be recommended as a new reference method. Each laboratory analyzed serial dilutions of normal specimens, stabilized material, and at least 60 patient specimens with a range of platelet counts from 1 to 400 x 10(3)/microL (1-400 x 10(9)/L). Pooled analysis of the serial dilutions showed that RBC-platelet and RBC-RBC coincidence events became negligible at sufficiently high dilutions (i.e., > 1:1,000). All laboratories demonstrated excellent intra-assay and acceptable interlaboratory precision. Two antibodies (CD61 and CD41) were used for identifying platelets and individually gave acceptable results, but in a minority of samples, staining differences were observed. The optimum method thus uses a double-labeling procedure with a final dilution factor of 1:1,000. The study demonstrated that this method meets the criteria for a reference platelet count.
منابع مشابه
A candidate reference method for uric acid in serum. II. Interlaboratory testing.
We describe the interlaboratory testing of a candidate Reference Method (Part I) for uric acid in serum. The method is based on the ultrasound spectrophotometric quantitation of uric acid before and after incubation with uricase. A comprehensive investigation involving 12 laboratories was organized to document the transferability, intra- and interlaboratory precision, and general reliability of...
متن کاملComparative Study of Four Platelet-Rich Plasma Methods for Preparing Platelet Concentrates
Background: Platelet preparations have been used for a wide variety of clinical applications such as hemorrhage, tissue engineering and cellular therapy. Platelet concentrates can be prepared by the apheresis method or from the whole blood using the Buffy-coat or Platelet-rich plasma methods. The purpose of this study was to compare four variations of platelet-rich plasma method based on double...
متن کاملCandidate reference method for determining creatinine in serum: method development and interlaboratory validation.
We describe a "high-performance" liquid chromatographic (HPLC) method for accurately determining creatinine in serum. After prechromatographic precipitation of protein, we performed isocratic ion-exchange chromatography with ultraviolet detection (234 nm). Analytical results showed linearity up to 1770 mumol/L, a detection limit of 22 mumol/L, an average analytical recovery of 101%, and a CV ra...
متن کاملIs automated platelet counting still a problem in thrombocytopenic blood?
CONTEXT Reliable platelet counting is crucial for indicating prophylactic platelet transfusion in thrombocytopenic patients. OBJECTIVE To evaluate the precision and accuracy of platelet counting for thrombocytopenic patients, using four different automated counters in comparison with the Brecher & Cronkite reference method recommended by the International Committee for Standardization in Hema...
متن کاملStatistical Analysis of a Round-Robin Measurement Survey of Two Candidate Materials for a Seebeck Coefficient Standard Reference Material
In an effort to develop a Standard Reference Material (SRM™) for Seebeck coefficient, we have conducted a round-robin measurement survey of two candidate materials-undoped Bi2Te3 and Constantan (55 % Cu and 45 % Ni alloy). Measurements were performed in two rounds by twelve laboratories involved in active thermoelectric research using a number of different commercial and custom-built measuremen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of clinical pathology
دوره 115 3 شماره
صفحات -
تاریخ انتشار 2001