Heat Exposure Control Using Non-refrigerated Water in Brazilian Steel Factory Workersa
نویسندگان
چکیده
To test an economically reasonable method to reduce thermal stress, we performed an alternated intervention-control study on 2 groups of 8 male steel workers performing the same jobs, using 2 l of water at ambient temperature (23.5°C ± 1.4), poured on the head and hands. Each group participated for 2 d as control and 2 d as intervention during 4 consecutive summer days in Brazil, 5 h per shift per day. Testing was done by: 1) recording of temperature by thermistors placed on the external ear canal through earplug, skin (chest, upper arm, inner thigh, outer calf) and clothes; 2) recording of heart rate; and 3) Wet Bulb Globe Temperature recording. The intervention was held hourly, when body weight and water intake were evaluated. Symptoms and subjective sensations were evaluated in the beginning and at the end of each shift. No differences were observed in external ear canal and skin temperatures. Subjective thermal sensation (p=0.018), sweat perception (p=0.043), and tiredness (p=0.028) presented positive statistically significant results when comparing intervention to control measurements. In conclusion, our results could not provide evidence that the proposed method cools the analyzed temperatures, although the subjective evaluation suggests a decrease in the head skin temperature, which could be a useful comfort measure.
منابع مشابه
Heat exposure control using non-refrigerated water in Brazilian steel factory workers.
To test an economically reasonable method to reduce thermal stress, we performed an alternated intervention-control study on 2 groups of 8 male steel workers performing the same jobs, using 2 l of water at ambient temperature (23.5 degrees C +/- 1.4), poured on the head and hands. Each group participated for 2 d as control and 2 d as intervention during 4 consecutive summer days in Brazil, 5 h ...
متن کاملMembrane oxygenator heat exchanger failure detected by unique blood gas findings.
Failure of components integrated into the cardiopulmonary bypass circuit, although rare, can bring about catastrophic results. One of these components is the heat exchanger of the membrane oxygenator. In this compartment, unsterile water from the heater cooler device is separated from the sterile blood by stainless steel, aluminum, or by polyurethane. These areas are glued or welded to keep the...
متن کاملOperational trends of a mini parabolic solar collector for agricultural purposes in a non-active solar environment
The mode of operation of mini parabolic solar panels made of germanium, mild steel and aluminium were investigated experimentally, as means of providing heated water on a farmland; the process was also modelled. Angular adjustments of the solar collectors from 70-90o were adopted in order to determine, the best material of construction for the parabolic solar collector and the angular orientati...
متن کاملHeat stress assessment according to the wet-bulb globe temperature (WBGT) index among workers of a steel mill in 2014
Background: Heat stress in the steel industry is considered as a serious threat to the health and safety of workers. A wide spectrum of complications and diseases from mild disorders such as burning sensation to fatal conditions such as thermal shock may occur due to uncontrolled thermal stress. In this study, heat stress assessment was performed according to the wet-bulb globe temperature (WBG...
متن کاملارزیابی میزان مواجهه کارگران با گرما و ارائه طرح کنترل تنش حرارتی در شرکت پروفیل
Background & Objectives : Exposure to heat is a significant problem in the Industries. The present study aimed at the evaluation of thermal risk, measurement of heat stress index, and proposing a plan for heat control in cutting and welding units in profile factory . Methods : The data of study was analyzed through the measurement of physical parameters with digital WBGT device...
متن کامل