PURPOSE To evaluate the clinical outcomes of cataract surgery using novel diffractive trifocal intraocular lenses (IOLs) in Koreans. METHODS This was a retrospective, consecutive, interventional study of cataract surgery using POD FineVision IOL implantation. Complete ophthalmologic examinations were performed preoperatively and postoperatively. Defocus curves were assessed over a range of +1.5 to -4.0 diopters in 0.5-diopter steps at one month postoperatively. Uncorrected distant visual acuity, uncorrected intermediate visual acuity, uncorrected near visual acuity, corrected distant visual acuity, distant-corrected intermediate visual acuity, and distant-corrected near visual acuity were assessed one month postoperatively, and manifest refraction was performed during every visit. RESULTS The study analyzed 31 eyes in 20 patients. There were statistically significant improvements in uncorrected distance visual acuity, uncorrected intermediate visual acuity, uncorrected near visual acuity, corrected distance visual acuity, distance-corrected intermediate visual acuity, and distance-corrected near visual acuity (p < 0.001). The final postoperative refractive outcomes showed statistically significant myopic shifts compared to the target refraction based on SRK/T, SRK-II, Haigis, and Hoffer Q formulas (p < 0.001). CONCLUSIONS POD FineVision IOLs provide stable visual restoration with improvements of near and intermediate vision in presbyopic eyes. POD FineVision IOLs show myopic shift in a Korean population; therefore, surgeons should be cautious when selecting IOL power in such patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Outcomes after Binocular Implantation of a New Trifocal Diffractive Intraocular Lens

Purpose. To evaluate visual, refractive, and contrast sensitivity outcomes, as well as the incidence of pseudophakic photic phenomena and patient satisfaction after bilateral diffractive trifocal intraocular lens (IOL) implantation. Methods. This prospective nonrandomized study included consecutive patients undergoing cataract surgery with bilateral implantation of a diffractive trifocal IOL (A...

متن کامل

Clinical outcomes of a new diffractive trifocal intraocular lens with Enhanced Depth of Focus (EDOF)

BACKGROUND To evaluate the clinical outcomes after the implantation of a new trifocal diffractive intraocular lens (IOL) combined with Enhanced depth of focus (EDOF) technology. METHODS The study enrolled 80 eyes of 40 patients who underwent cataract surgery with bilateral implantation of a diffractive trifocal IOL (Reviol Tri-ED) designed with a combination of enhanced depth of focus. Mean a...

متن کامل

Visual and refractive outcomes after implantation of a fully diffractive trifocal lens

BACKGROUND The purpose of this study was to record the visual outcomes of patients treated by six surgeons after implantation of a trifocal lens. METHODS The setting for this study comprised six ophthalmology units and eye clinics in Belgium and France, with a coordinating center in France, and data management and statistical analysis in France and Belgium. Ninety-four eyes from 47 patients w...

متن کامل

Visual performance, reading ability and patient satisfaction after implantation of a diffractive trifocal intraocular lens

Purpose To evaluate visual outcome, reading performance, contrast sensitivity, and patient satisfaction after cataract surgery with implantation of a diffractive trifocal intraocular lens (IOL). Patients and methods A total of 42 eyes (21 patients) underwent cataract surgery with implantation of the trifocal IOL AT LISA tri 839MP. Visual acuity, contrast sensitivity, and patient satisfaction ...

متن کامل

Comparative analysis of the visual performance after cataract surgery with implantation of a bifocal or trifocal diffractive IOL.

PURPOSE To evaluate and compare the visual, refractive, contrast sensitivity, and aberrometric outcomes with a diffractive bifocal and trifocal intraocular lens (IOL) of the same material and haptic design. METHODS Sixty eyes of 30 patients undergoing bilateral cataract surgery were enrolled and randomly assigned to one of two groups: the bifocal group, including 30 eyes implanted with the bi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2018