Optimization of RF excitation to maximize signal and T2 contrast of tissues with rapid transverse relaxation.

نویسندگان

  • Michael Carl
  • Mark Bydder
  • Jiang Du
  • Atsushi Takahashi
  • Eric Han
چکیده

Ultrashort echo time MRI requires specialized pulse sequences to overcome the short T(2) of the MR signal encountered in tissues such as ligaments, tendon, or cortical bone. Theoretical work is presented, supported by simulations and experimental data on optimizing the radiofrequency excitation to maximize signal-to-noise ratio and contrast-to-noise ratio. The theoretical calculations and simulations are based on the classic Bloch equations and lead to a closed form expression for the optimal radiofrequency pulse parameters to maximize the MR signal in the presence of rapid T(2) decay. In the steady state, the spoiled gradient recalled echo signal amplitude in response to the radiofrequency excitation pulses is not maximized by the classic Ernst angle but by a more general criterion we call "generalized Ernst angle." Finally, it is shown that T(2) contrast is maximized by flipping the magnetization at the Ernst angle with a radiofrequency pulse duration proportional to the targeted T(2). Experimental studies on short T(2) phantoms confirm these optimization criteria for both signal-to-noise ratio and contrast-to-noise ratio.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Short T2 Excitation and Long T2 Suppression RF Pulses

Introduction: Ultrashort echo time (UTE) MRI requires specialized pulse sequences to overcome the short T2 relaxation of the MR signal encountered in tissues such as ligaments, tendon or cortical bone. Imaging short T2 tissues is achieved in UTE by acquiring the Free Induction Decay (FID) of the MR signal as soon after the end of the RF excitation pulse as possible. This is typically accomplish...

متن کامل

MR Spin Behavior During RF Pulses: T2 vs. T2' Relaxation

Introduction: We investigate the behavior of the MR magnetization vector during RF pulses in the presence of rapid transverse relaxation. The transverse relaxation is divided into two separate mechanisms: Homogeneously broadened lines which resulting in irreversible T2 amplitude decay, and inhomogeneously broadened lines resulting in dephasing and in principle refocusable T2’. While the two dif...

متن کامل

Fast 3D UTE Imaging of Knee Connective Tissues on a Clinical 3T Scanner

INTRODUCTION Connective tissues in human knee joint, such as articular cartilage, menisci, or ligaments, have short transverse relaxation time components (T2 ~5ms) due to their collagen-rich micro-structures (1). To image those short-T2 components with minimum signal loss, special pulse sequences capable of ultra-short echo time (UTE) are desired. A number of UTE sequences have been developed i...

متن کامل

Fast Spin Echo Imaging

In conventional spin echo (SE) imaging, the longitudinal magnetization (that is generated by the presence of the main magnetic field, B0) is tipped into the transverse plane using a radiofrequency (RF) pulse that tips the magnetization 90 degrees. Once in the transverse plane, the magnetization rotates, or precesses, around the axis of the main magnetic field. As the transverse magnetization pr...

متن کامل

T2*-compensated Transmit SENSE RF pulses

Introduction Selective excitation in more than one dimension is plagued by effects that are due to the long duration of the RF pulses and gradient trajectories needed. B0 off-resonances, for example, dephase magnetization contributions created at different points in time during the excitation process. As a consequence, these contributions do not add up consistently which causes artifacts in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 64 2  شماره 

صفحات  -

تاریخ انتشار 2010