Circulatory Dynamics During Pulmonary Vein Isolation Using the Second‐Generation Cryoballoon

نویسندگان

  • Takatsugu Kajiyama
  • Shinsuke Miyazaki
  • Tomonori Watanabe
  • Kazuya Yamao
  • Shigeki Kusa
  • Miyako Igarashi
  • Hiroaki Nakamura
  • Hitoshi Hachiya
  • Yoshito Iesaka
چکیده

BACKGROUND Circulatory dynamics change during pulmonary vein (PV) isolation using cryoballoons. This study sought to investigate the circulatory dynamics during cryoballoon-based PV isolation procedures and the contributing factors. METHODS AND RESULTS This study retrospectively included 35 atrial fibrillation patients who underwent PV isolation with 28-mm second-generation cryoballoons and single 3-minute freeze techniques. Blood pressures were continuously monitored via arterial lines. The left ventricular function was evaluated with intracardiac echocardiography throughout the procedure in 5 additional patients. Overall, 126 cryoapplications without interrupting freezing were analyzed. Systolic blood pressure (SBP) significantly increased during freezing (138.7±28.0 to 148.0±27.2 mm Hg, P<0.001) and sharply dropped (136.3±26.0 to 95.0±17.9 mm Hg, P<0.001) during a mean of 21.0±8.0 seconds after releasing the occlusion during thawing. In the multivariate analyses, the left PVs (P=0.008) and lower baseline SBP (P<0.001) correlated with a larger SBP rise, whereas a higher baseline SBP (P<0.001), left PVs (P=0.017), lower balloon nadir temperature (P=0.027), and female sex (P=0.045) correlated with larger SBP drops. These changes were similarly observed regardless of preprocedural atropine administration and the target PV order. PV occlusions without freezing exhibited no SBP change. PV antrum freezing without occlusions similarly increased the SBP, but the SBP drop was significantly smaller than that with occlusions (P<0.001). The SBP drop time-course paralleled the left ventricular ejection fraction increase (66.8±8.1% to 79.3±6.7%, P<0.001) and systemic vascular resistance index decrease (2667±1024 to 1937±513 dynes-sec/cm2 per m2, P=0.002). CONCLUSIONS With second-generation cryoballoon-based PV isolation, SBP significantly increased during freezing owing to atrial tissue freezing and dropped sharply after releasing the occlusion, presumably because of the peripheral vascular resistance decrease mainly by circulating chilled blood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon.

BACKGROUND The use of second-generation cryoballoon for pulmonary vein isolation in patients with paroxysmal atrial fibrillation has demonstrated encouraging acute and mid-term results. Long-term outcome data are not yet available. METHODS AND RESULTS Fifty patients (18 women; mean age, 61±11 years; mean left atrial diameter, 43±5 mm) with paroxysmal (36 of 50 patients; 72%) or short-standing...

متن کامل

Electromyographic monitoring for prevention of phrenic nerve palsy in second-generation cryoballoon procedures.

BACKGROUND Electromyography-guided phrenic nerve (PN) monitoring using a catheter positioned in a hepatic vein can aid in preventing phrenic nerve palsy (PNP) during cryoballoon ablation for atrial fibrillation. We wanted to evaluate the feasibility and efficacy of PN monitoring during procedures using second-generation cryoballoons. METHODS AND RESULTS This study included 140 patients (43 wo...

متن کامل

Spastic occlusion of coronary artery during cryoballoon pulmonary vein isolation

Introduction Recently, pulmonary vein isolation (PVI) with cryoballoon (CB) has been widely accepted as treatment for atrial fibrillation (AF). Especially, second-generation CB (Arctic Front Advance, Medtronic, Inc, Minneapolis, MN) has a high cooling effect, which can achieve durable lesions of pulmonary vein (PV) antrum and better clinical outcomes. On the other hand, several complications, s...

متن کامل

Impact of freezing time and balloon size on the thermodynamics and isolation efficacy during pulmonary vein isolation using the second generation cryoballoon.

BACKGROUND The differences in ablation characteristics of freezing time and balloon size using second generation cryoballoon are still unknown. METHODS AND RESULTS Twenty-six dogs underwent pulmonary vein (PV) isolation. Balloon and tissue temperatures (left atrial-PV junction, phrenic nerve, and internal esophagus) were monitored. The ablation duration was randomized to either 3 or 4 minutes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017