Double-pass measurement of retinal image quality in the chicken eye.

نویسندگان

  • Nancy J Coletta
  • Susana Marcos
  • Christine Wildsoet
  • David Troilo
چکیده

PURPOSE The chicken, Gallus gallus domesticus, is used as an animal model to study the development of refractive error. Although vision is important in determining the eye's refractive state, relatively little is known about the retinal image quality of the chicken eye. An objective double-pass technique was used to measure the optical quality of the eyes of White Leghorn chickens. METHODS Measurements were made on 21 eyes of six untreated birds and eight experimental birds that were members of a study of refractive development. Ages ranged from 3 to 6 weeks, and refractions ranged from -1.29 to +0.58 D in the untreated eyes and -4.58 to +10.17 D in the experimental eyes. The measurements were made under general anesthesia combined with either cycloplegia or ciliary nerve section. Proper optical alignment of the eye was achieved with the aid of a TV monitor, CCD camera, and an infrared source. A 543-nm laser point source was focused on the retina, and the double-pass aerial image was collected by a high-resolution CCD camera. Refractive errors were corrected with trial lenses, using a bracketing method to optimize the retinal images. Both the full width at half-maximum of the double-pass aerial image and the single-pass modulation transfer function were used as objective estimates of the optical quality. RESULTS The mean full width at half-maximum value in eyes of the untreated birds was 1.60 min arc for a 4.50-mm mean pupil diameter. Optical quality tended to be worse in the experimental myopic eyes. CONCLUSIONS The optical quality of the chicken eye measured under monochromatic conditions meets or may even exceed the neural limits of spatial acuity based on anatomical estimates of ganglion cell spacing. The data also suggest that optical quality is worse in myopic eyes, which is consistent with studies of human eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polarization and retinal image quality estimates in the human eye.

We have previously studied how polarization affects the double-pass estimates of the retinal image quality by using an imaging polarimeter [Opt. Lett. 24, 64 (1999)]. A series of 16 images for independent combinations of polarization states in the polarimeter were recorded to obtain the spatially resolved Mueller matrices of the eye. From these matrices, double-pass images of a point source for...

متن کامل

Odd aberrations and double-pass measurements of retinal image quality.

We investigated the formation of the aerial image in the double-pass method to measure the optical quality of the human eye. We show theoretically and empirically that the double pass through the eye's optics forces the light distribution in the aerial image to be an even-symmetric function even if the single-pass point-spread function is asymmetric as a result of odd aberrations in the eye. Th...

متن کامل

Retinal image quality in the human eye as a function of the accommodation

The changes in the retinal image quality with accommodation in the human eye were studied by using a near-infrared double-pass apparatus. A slightly better modulation transfer function (MTF) in the unaccommodated eye with respect to the accommodated eye was found when using an artificial pupil with a fixed diameter. The technique allows the estimation of the MTF of the accommodated eye discount...

متن کامل

Compliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography

Introduction Blue light is a part of the spectrum with the highest energy content, which can reach the retina. The damage that it can cause to the retina is called photochemical or blue-light retinal injury. For the retinal injury assessment of the photochemical and aphakic retinal hazards in the wavelength range of 300-700 nm, use of effective spectral radiance limits (W.m-2.sr-1) seems to be...

متن کامل

Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrument.

PURPOSE Wavefront sensors provide quite useful information on the optical quality of the eye. However, in eyes where very high-order aberrations and scattered light are prominent, wavefront sensors may overestimate retinal image quality. This study showed that, in those cases, the double-pass technique is a complementary tool for better estimation of ocular optical quality. METHODS A double-p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optometry and vision science : official publication of the American Academy of Optometry

دوره 80 1  شماره 

صفحات  -

تاریخ انتشار 2003