The first operation of control system at the SPring-8 storage ring
نویسندگان
چکیده
The control system based on the standard model of the UNIX and VMEbus system has successfully performed accelerator operation with 8GeV electron beams. The software architecture of the control system designed with the client/server scheme has well operated over the distributed computing environment with the FDDI opticalfiber network. The relational database system has been widely used for machine data acquisition, archiving, and management of equipment parameters. The results of the control system from the experience of the storage ring operation are summarized. 1 Status of SPring-8 The SPring-8 storage ring, a third generation light-source, has been started its beam commissioning since March 13th, 1997. On March 25th, the 8GeV electron beam was captured by the RF system, and the first synchrotron radiation light from a bending magnet was observed on the next day. The commissioning of the storage ring with insertion devices has been continued with 20mA beam current until October 3rd. After the commissioning, the beam lifetime reaches up to around 70hours at 20mA. Now, the synchrotron light from ten beamlines consisting of seven insertion devices (1 wiggler and 6 undulators) and three bending magnets are available.
منابع مشابه
Vacuum Conditioning and Beam Lifetime of the Spring-8 Storage Ring
The installation of the vacuum system of the SPring-8 storage ring was completed during 1996. Most of the vacuum chambers are made of aluminum alloy. The main pumping system is a mixed one consisting of NEG strips, DIP, SIP, and LNP. In addition to the standard treatments for ultrahigh vacuum components, dust-controlled procedure was adopted in the manufacturing and the installation processes. ...
متن کاملData Acquisition System with Database at the SPring-8 Storage Ring
The SPring-8 storage ring control system has two kinds of access to the machine components, that is, an interactive operation and a periodic reading/monitoring operation. This paper describes the later. The machine status are periodically taken by processes on VME CPU(named the poller) and stored into shared memory. A process(collector client) running on the operator consoles cyclically collect...
متن کاملControl System of the SPring-8 Storage Ring
The SPring-8 storage ring is under construction and will be commissioned in February 1997. The design for the control system of the storage ring adopted the so-called Standard Model concept. VMEbus is used as the front-end control system and is widely distributed around the 1436m circumference of the storage ring. The VMEbus is controlled by a single-board-computer with a RISC processor. The VM...
متن کاملRECENT PROGRESS OF THE SPring-8 FACILITY
Since October 1997, the SPring-8 facility has been operated well and provided high quality photon beams for users. Over this period, various kinds of improvements have been carried out to achieve brilliant and stable photon beams and to make the most of 8-GeV potentiality. At the same time R&D has continued for future radiation sources. In these activities, the largest achievement has been the ...
متن کاملOperation and Control of Hybrid Fuel Cell/ Energy Storage Distributed Power Generation System during voltage Sag Conditions
This paper presents a control strategy for fuel cell/energy storage power generation system during voltage sag conditions. The hybrid DC power sources are connected to grid using power electronic converters include DC-DC converter and grid connected voltage source inverter. The power from hybrid power sources is controlled during voltage sag by designing of control strategy for DC-DC converter....
متن کامل