320-slice CT and myocardial bridge.

نویسندگان

  • Antonietta Evangelista
  • Francesco Pelliccia
  • Alessio Arrivi
  • Carlo Gaudio
چکیده

1 of 2 DESCRIPTION A 29-year-old professional athlete was referred for cardiac evaluation after a syncope occurring during strenuous exercise. Twelve-lead ECG showed Brugada-like pattern ( fi gure 1 ), but both fl ecainide and genetic tests were negative. ECG Holter and echocardiogram were normal. ECG stress test showed no signifi cant ST-segment changes. In order to rule out coronary artery disease or anomalies, 320-slice multi detector CT (Aquilon One; Toshiba Medical Systems Inc,Tokyo, Japan) was done with settings at 100 mV and 320 mA (heart rate was 50 beats/min). Eighty millilitre of contrast agent (Ultravist 370; Bayer Schering Pharma AG, Berlin, Germany) were injected intravenously at a rate of 5.5 ml/s, followed by 60 ml of saline at the same rate. The total radiation dose was only 2.4 mSv. The scan showed two typical myocardial bridges of the left anterior descending artery, with intramural tracts of 10 mm in the mid-segment and of 15 mm in the distal segment ( fi gure 2 , upper and lower panels). No evidence of stenosis of coronary arteries was found. CT can rule out coronary artery disease in very low-risk subjects and detect myocardial bridging. 1 With the introduction of 320-slice multi-slice CT, scanning of the entire heart has become possible in a single heart beat with a very low dose of radiation. 2 Thus, this novel technique is particularly suited for cases (ie, such as young professional athletes) in whom is essential to rule out any possible coronary artery disease or anomaly avoiding more invasive procedures. Images in...

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gender Differences in Types and Frequencies of Coronary Artery Anomalies and Myocardial Bridge in 10,457 Chinese Undergoing 320-Slice Computed Tomography

Varied frequencies of coronary artery anomalies (CAAs) and myocardial bridge (MB) exist in previous studies. Race and gender may play a role. The present study aimed to investigate the gender differences in types and frequencies of coronary artery anomalies (CAAs) and myocardial bridge (MB) in Chinese undergoing 320-slice coronary computed tomography. The authors assessed prospectively the reco...

متن کامل

Right Pulmonary Artery to Left Atrial Fistula Confirmed by 320-slice Computerized Tomography

To the Editor: Right pulmonary artery‐left atrial fistula (RPALAF) is an extremely rare congenital cardiovascular malformation that may be difficult to diagnose by clinical symptoms. High resolution computed tomographic (CT) gives a clear view of cardiovascular and can provide an accurate diagnosis, and it has not been reported in the last literature date though 320‐slice CT scan giving these c...

متن کامل

Assessment of Myocardial Bridge and Mural Coronary Artery Using ECG-Gated 256-Slice CT Angiography: A Retrospective Study

Recent clinical reports have indicated that myocardial bridge and mural coronary artery complex (MB-MCA) might cause major adverse cardiac events. 256-slice CT angiography (256-slice CTA) is a newly developed CT system with faster scanning and lower radiation dose compared with other CT systems. The objective of this study is to evaluate the morphological features of MB-MCA and determine its ch...

متن کامل

Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences

OBJECTIVE To explore the usefulness of 320-slice CT angiography (CTA) for evaluating the course of the anterior ethmoidal artery (AEA) and its relationship with adjacent structures by using three-dimensional (3D) spin digital subtraction angiography (DSA) as standard reference. MATERIALS AND METHODS From December 2008 to December 2010, 32 patients with cerebrovascular disease, who underwent b...

متن کامل

Study of 320-Slice Dynamic Volume CT Perfusion in Different Pathologic Types of Kidney Tumor: Preliminary Results

OBJECTIVE To investigate microcirculatory differences between pathologic types of kidney tumor using 320-slice dynamic volume CT perfusion. METHODS Perfusion imaging with 320-slice dynamic volume CT was prospectively performed in 85 patients with pathologically proven clear cell renal cell carcinoma (RCC) (n = 66), papillary RCC (n = 7), chromophobe RCC (n = 5), angiomyolipoma (AML) with mini...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMJ case reports

دوره 2011  شماره 

صفحات  -

تاریخ انتشار 2011