Forced Convection Model Of Fan Plate-Finned Tube Type Heat Exchanger At Low Reynolds Numbers

نویسندگان

  • T. Inagaki
  • K. Komine
  • K. Wang
  • Takefumi INAGAKI
  • Kenji KOMINE
  • Jun SAKURAGI
چکیده

The forced convection experiment of fan plate-finned tube heat exchangers which are mainly used in air conditioners and the forced convection model have been studied for which the heat transfer effect of this type exchangers has not been proposed by a model. All measurements were made when there is no refrigerant flow in the pipe at Reynolds's number of 580. According to the experiment results, basing on the threshold value that is defined as the strength of virtual average flow of which the free flow velocity capacity was used as a standard, the forced convection effect of the flow between the finned tube set and the fan can be divided into two regions. To fully utilize the heat transfer effect of the fan plate-finned tube heat exchangers, the model of the forced convection is proposed by velocity scale and length scale here.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Finned-Tube Heat Exchanger with Minimizing the Entropy Production rate

A compact fin-tube heat exchanger is used to transfer current fluid heat inside the tubes into the air outside. In this study, entropy production and optimized Reynolds number for finned-tube heat exchangers based on the minimum entropy production have been investigated. As a result, the total entropy of compact heat exchangers, which is the summation of the production rate of fluid entropy ins...

متن کامل

Characteristics of forced convection heat transfer in vertical internally finned tube

This work presents a numerical investigation of a vertical internally finned tube subjected to forced convection heat transfer. The governing equations were solved numerically using the control volume technique. Nusselt number, Nu, and friction factor multiplied by Reynolds number, fRe, are influenced greatly by the height and number of the radial fins. The velocity and temperature distribution...

متن کامل

Investigating the effect of magnetic field on the forced convection of cross-corrugated triangular channels

Cross-corrugated triangular channels increase heat transfer in heat exchangers. The mixing effect increases the heat transfer coefficient at the surfaces. In this study, the fluid flow and heat transfer in a triangular corrugated channel are modeled under two constant heat fluxes and different Reynolds numbers. In order to validate, k-ω turbulence model is used. Also, the effect of magnetic fie...

متن کامل

Full Analysis of Low Finned Tube Heat Exchangers

In this paper, first the governing parameters characterizing low-finned tubes are reviewed. Second, the more important of the available performance correlations are compared with the available experimental data. The most reliable one can be employed to develop a pressure drop relationship, which has already been used in an algorithm for exchanger sizing. Also a means for the identification of a...

متن کامل

Minimization of Entransy Dissipations of a Finned Shell and Tube Heat Exchanger

Improving heat transfer and performance in a radial, finned, shell and tube heat exchanger is studied in this study. According to the second law of thermodynamics, the most irreversibilities of convective heat transfer processes are due to fluid friction and heat transfer via finite temperature difference. Entransy dissipations are due to the irreversibilities of convective heat transfer. There...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014