Simultaneous quantification of five bioactive components of Acanthopanax senticosus and its extract by ultra performance liquid chromatography with electrospray ionization time-of-flight mass spectrometry.
نویسندگان
چکیده
A simple and reliable ultra performance liquid chromatography coupled with electrospray ionization time-of-flight mass spectrometry method (UPLC-TOF-MS) was developed and validated for the simultaneous determination of the major bioactive constituents in Acanthopanax senticosus and its extract. The separation of five compounds was performed on a UPLC™ HSS T3 column (100 mm × 2.1 mm, 1.7 μm) with gradient elution using a mobile phase consisting of 0.1% aqueous formic acid and acetonitrile containing 0.1% formic acid. All targeted compounds (syringin, chlorogenid acid, caffeic acid, eleutheroside E and isofraxidin) were baseline separated within 5.3 min in samples, which represented an approximate six-fold reduction in the analysis time in comparison to published HPLC method. Quantitation was carried out working in the V mode using the narrow widow extracted ion chromatograms (nwXICs) of each compound (extracted using a 20 mDa window). Furthermore, all calibration curves showed good linearity (r > 0.999) within the test ranges. The precision was evaluated by intra- and inter-day tests, which revealed relative standard deviation (RSD) values of less than 3.88%. The recoveries for the quantified compounds were between 96.3% and 103.7%, with RSD values below 2.89%. According to the literature, this study represents the first investigation of the simultaneous analysis of multiple components and the method can be applied to determine the amounts of the major compounds in Acanthopanax senticosus and its extract by UPLC-TOF-MS.
منابع مشابه
Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)
The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملQSRR models of veterinary drugs in milk in ultra-performance liquid chromatography coupled to time of flight mass spectrometry
The veterinary drugs residues are also important pollutants found in milk, since veterinary drugs are commonly used in cattle management. Considering the role of milk in human nutrition and its wide consumption throughout the world, it is very important to ensure the milk quality. A quantitative structure–retention relationship (QSRR) was developed using the partial least square (PLS), Kernel P...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Molecules
دوره 17 7 شماره
صفحات -
تاریخ انتشار 2012