A Comparison of Zirconia and Titanium Abutments for Microleakage.

نویسندگان

  • Mohamed I Abdelhamed
  • Jeffrey D Galley
  • Michael T Bailey
  • William M Johnston
  • Julie Holloway
  • Edwin McGlumphy
  • Binnaz Leblebicioglu
چکیده

BACKGROUND Microleakage through the interface has been documented in implant systems with titanium (Ti) abutments. There is a current increase in the use of zirconia (Zi) abutments especially in esthetic zone in where higher risk of visible metal color through the peri-implant tissues exists. PURPOSE The aim of the present in vitro study is to evaluate the leakage at the implant fixture-abutment interface with two different screw-retained abutment systems at different torque values in a nonloading condition. MATERIALS AND METHODS In vitro study design included four groups (Ti and Zi torqued at 25 and 15 Ncm [N = 8/group]). Microcomputed tomography (micro-CT) was chosen to detect microgap. Microleakage from the implant chamber to the external milieu was evaluated using limulus amebocyte lysate (LAL) test, while microleakage from external milieu to the implant chamber was evaluated using toluidine blue dye (TBD) and colorimeter. RESULTS Micro-CT images did not reveal any microgap. LAL test showed that there is a time-, abutment-, and torque-dependent increase in microleakage (p = .001) with Zi torqued at 15 Ncm having higher leakage with time compared with Ti torqued at 15 Ncm (p = .002), as well as Zi torqued at 15 Ncm having higher leakage with time compared with Zi torqued at 25 Ncm (p = .01). TBD test showed a nonsignificant increase in microleakage with higher leakage related to titanium abutment groups (p > .05). Repeated torque/antitorque handling differentially affected microleakage (p = .01). CONCLUSIONS Within the limits of this study, there is a statistically significant difference in bidirectional microleakage with time, abutment type, and torque values being major players for leakage from internal implant chamber to external milieu, while the abutment type and time but not the torque value being important factors for leakage from external milieu into implant chamber in nonloading condition. Future studies are needed to determine peri-implant health around Zi abutments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...

متن کامل

Evaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro

Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...

متن کامل

Assessment and comparison of retention of zirconia copings luted with different cements onto zirconia and titanium abutments: An in vitro study

AIM The purpose of this in vitro study was to assess and compare the retention of zirconia copings luted with different luting agents onto zirconia and titanium abutments. MATERIALS AND METHODS Titanium and zirconia abutments were torqued at 35 N/cm onto implant analogs. The samples were divided into two groups: Group A consisted of four titanium abutments and 32 zirconia copings and Group B ...

متن کامل

Comparative Evaluation of Microgap at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract   Background and Aim : Microgap in the implant-abutment interface is one of the main challenges in the treatment of two-piece implants. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microgap at implant-abutment interface area under oblique cyclic loading in vitro. Methods and Materials In this in vitro study, 12 implant-abutment assemb...

متن کامل

مقایسه مقاومت شکست و نوع شکست اباتمنت‌های زیرکونیایی مختلف در مقایسه با اباتمنت‌های تیتانیومی

Background and Aims: One of the decisive factors on the final esthetic results of implant treatment is the abutment material. Ceramic abutments are nowadays very popular in this regard. The purpose of this study was to compare the fracture resistance of three zirconia abutments with titanium abutment. Materials and Methods: Four groups of abutments (five specimens in each) were prepared. The a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical implant dentistry and related research

دوره 17 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2015