Lithium dilution cardiac output measurement in oleic acid-induced pulmonary edema.

نویسندگان

  • Tadayoshi Kurita
  • Koji Morita
  • Hiroyuki Kawasaki
  • Kiyoyasu Fujii
  • Tomiei Kazama
  • Shigehito Sato
چکیده

OBJECTIVE To determine whether lung injury influences the accuracy of lithium dilution cardiac output (CO) measurement. DESIGN Animal experimental study. SETTING Animal experimental laboratory. PARTICIPANTS Swine (n = 23) weighing 26.4 +/- 2.47 kg (mean +/- SD). INTERVENTIONS The animals were anesthetized and tracheotomized, then a pulmonary artery catheter was inserted into the right jugular vein, and a catheter (18G) was placed in the femoral artery. After median sternotomy and pericardiotomy, a left ventricular catheter (18G) was directly inserted. CO was measured by giving a bolus injection of lithium chloride into either the right atrium or the left ventricle in each animal. After control measurements, permeability pulmonary edema was initiated by infusing oleic acid into the central vein (injury). About 2 hours after oleic acid infusion, CO measurements were repeated in the same manner as the control measurement had been taken. MEASUREMENTS AND MAIN RESULTS Under each condition, right atrium lithium injection was similar to left ventricle lithium injection. The mean of these differences at injury (-0.06 +/- 0.55 L/min) was the same as that at control (-0.05 +/- 0.36 L/min). CONCLUSIONS Although the variability of lithium dilution CO measurement after oleic acid-induced pulmonary edema was greater than that of the control, this technique was acceptable even in cases of lung injury.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output.

A new indicator dilution technique for measurement of cardiac output is described. Lithium chloride is injected via a central venous catheter and its dilution curve measured in arterial blood using a lithium-selective electrode. We assessed the lithium dilution cardiac output measurement (LiDCO) and a conventional thermodilution cardiac output measurement (ThDCO) by comparing the results of bot...

متن کامل

Regional measurements of pulmonary edema by using magnetic resonance imaging.

A three-dimensional magnetic resonance imaging (MRI) method to measure pulmonary edema and lung microvascular barrier permeability was developed and compared with conventional methods in nine mongrel dogs. MRIs were obtained covering the entire lungs. Injury was induced by injection of oleic acid (0.021-0.048 ml/kg) into a jugular catheter. Imaging followed for 0.75-2 h. Extravascular lung wate...

متن کامل

Evaluation of (1-sarcosine, 8-isoleucine) angiotensin II as a therapeutic agent for oleic acid-induced pulmonary edema.

(1-Sarcosine, 8-isoleucine) angiotensin II was assessed as a therapeutic agent for acute respiratory distress syndrome with oleic acid pulmonary edema in sheep used as an experimental model. Under general anesthesia with controlled mechanical ventilation with 100% oxygen, 32 sheep received oleic acid (0.075 ml/kg) intravenously. After oleic acid infusion, 20 animals were treated with continuous...

متن کامل

Effects of indomethacin and PEEP on oleic acid induced pulmonary oedema in rabbits.

This study was designed to determine whether indomethacin, a suggested treatment for adult respiratory distress syndrome (ARDS), would inhibit the efficacy of positive end-expiratory pressure (PEEP) in an animal model of ARDS. Functional residual capacity (FRC), alveolar-to-arterial oxygen difference (A-aPo2) and total lung water were measured in rabbits: 30 controls and 30 with oleic acid indu...

متن کامل

Measurement of stroke volume from pulmonary artery pressure record in man.

Stroke volume was determined from the pulmonary artery pressure record by application of the pulse contour method. Pulmonary artery pressure records were obtained in 17 patients using a high fidelity catheter-tip pressure transducer and simultaneous measurements of cardiac output were obtained from indicator dilution curves. The formula used was SV = KP sa (i plus T s/Td) where Psa is the plani...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiothoracic and vascular anesthesia

دوره 16 3  شماره 

صفحات  -

تاریخ انتشار 2002