Comparison of left ventricular volumes and ejection fraction assessment by two-dimensional echocardiography compared with gated myocardial spect in patients with ischemic cardiomyopathy.
نویسندگان
چکیده
AIM The aim of this study was to assess accuracy of echocardiography in the measurement of left ventricular ejection fraction (LVEF), enddiastolic volume (EDV) and endsystolic volume (ESV) compared with gated SPECT. METHODS A total of 70 patients with left ventricular systolic dysfunction were enrolled to study. Median of the time interval between gated SPECT and echocardiography was 1 hour. RESULTS Echocardiography was in good agreement with gated SPECT for quantification of LVEF by using Simpson's method in triplane (r=0.88, p<0.001), biplane (r=0.83, p<0.001) and monoplane apical four chamber projections (A4CH) (r=0.71, p<0,001). LVEF measured by SPECT (36.6+/-11.5%) was non-significantly higher then triplane (35.9+/-10%, median dif. 0.4%), biplane (35.7+/-10%, median dif. 0.7%), A4CH monoplane (36.6+/-12.2%, median dif. 0.1%). Echocardiography correlated with SPECT in quantification of EDV using triplane (r=0.8, p<0.001), biplane (r=0.81, p<0.001) and monoplane echocardiography (r=0.76, p<0.001). EDV measured by SPECT (201.1+/-72.5 ml) was significantly different and higher then triplane (174.4,5+/-60.8 ml, median dif. 22.8), biplane (170.9+/-58.4, median dif. 28 ml) and monoplane echocardiography (173.7+/-59.3, median dif. 85.7 ml). Echocardiography correlated with SPECT in quantification of ESV by triplane (r=0.87, p<0.001), biplane (r=0.86, p<0.001) and monoplane echocardiography (r=0.83, p<0.001). ESV measured by SPECT (133.1+/-64.3) was significantly different then triplane (115.1+/-52.1, median dif. 17 ml), biplane (113.2+/-51.5, median dif. 15.5 ml) and A4CH monoplane echocardiography (112.5+/-48.8, median dif. 17.2 ml). CONCLUSION Echocardiography is a valid tool for LVEF assessment and systematically underestimates LV volumes compared with gated SPECT in patients with LV systolic dysfunction.
منابع مشابه
Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings
Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...
متن کاملDiastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملThe prognostic value of stress/rest gated myocardial perfusion SPECT in patients with known or suspected coronary artery disease
Introduction:Gated myocardial perfusion SPECT has diagnostic and prognostic values in coronary artery disease (CAD). We tried to determine prognostic values of the left ventricular perfusion & functional indices as well as transient left ventricular dilation (TID) derived from gated myocardial perfusion SPECT. Methods: 1820patients who underwent gated myo...
متن کاملPrediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography
Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...
متن کاملNormal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT
Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia
دوره 154 1 شماره
صفحات -
تاریخ انتشار 2010