Improvement of Quantitative MRI using Radial GRAPPA in Conjunction with IR-TrueFISP
نویسندگان
چکیده
T1 [ms] T2 [ms] M0 [a.U.] SE KWIC SE KWIC SE KWIC 1 1177 1054 1071 890 867 790 2,52 1,97 1,87 2 752 760 779 649 677 674 2,18 1,78 1,67 3 569 570 579 482 486 526 1,8 1,61 1,49 4 474 452 450 378 379 425 1,78 1,52 1,38 5 352 359 382 317 419 310 1,84 1,34 1,25 6 51 58 55 34 48 10 1,84 1,05 2,37 7 65 73 52 43 15 68 1,85 2,52 1,42 8 81 88 75 54 18 33 1,86 2,84 2,03 9 115 111 108 85 47 78 1,94 2,37 2,13 10 226 200 205 167 161 170 2,21 2,39 2,29 11 311 294 297 268 275 277 1,74 1,44 1,32 Bottle rGRAPPA rGRAPPA rGRAPPA
منابع مشابه
Accelerated delayed enhancement imaging of myocardial infarction with through-time radial GRAPPA
Background Delayed contrast enhancement (DCE) imaging is a well-established MRI technique for the evaluation of myocardial infarction (MI) and tissue viability [1]. Inversion-recovery (IR) is used to visualize the hyperenhanced regions of scar after injection of Gd-DTPA. Mid-diastolic segmented k-space coverage is typical, requiring several heartbeats to reconstruct an image [2]. More recently,...
متن کاملQuantitative perfusion measurement of liver metastasis using DCE-MRI: Comparing a 3D-Flash vs. a IR-trueFISP protocol within a clinical phase II study
1. Scheffler K. Magn Reson Med. 2001 Apr; 45(4): 720-3. 3. Tofts PS, et. al. J Magn Reson Imaging. 1999 Sep;10(3): 223-32. 2. Scheffler K., Hennig J. Magn Reson Med. 2003 Apr; 49(4): 781-3. 4. Evelhoch JL. J Magn Reson Imaging. 1999 Sep; 10(3): 254-9. Quantitative perfusion measurement of liver metastasis using DCE-MRI: Comparing a 3D-Flash vs. a IR-trueFISP protocol within a clinical phase II ...
متن کاملRapid 3D Relaxation Time and Proton Density Quantification Using a Modified Radial IR TrueFisp Sequence
Introduction: A promising approach for the simultaneous quantification of proton density, T1 and T2 is the IR TrueFISP sequence proposed by Schmitt et al. [1]. This sequence consists of an inversion pulse followed by a series of TrueFISP acquisitions, observing a quasirelaxation towards the steady-state. However, this sequence requires a delay between individual segments in order to allow the m...
متن کاملAccurate T1 and T2 Maps Obtained with Ir-truefisp Calibrated by a Patient Driven Model
Introduction: As the cure rate for childhood Acute Lymphoblastic Leukemia (ALL) approaches 95%, an increasing amount of research is being devoted to studying the long-term effects of the treatment for ALL which can lead to a variety of debilitating side effects, including neurocognitive deficits. Analysis of brain morphology of ALL survivors has shown that these patients display white matter (W...
متن کاملQuantitative g-factors for radial GRAPPA
Introduction: Recently, a theoretical framework for quantitative estimation of the non-uniform noise enhancement in GRAPPA reconstructions has been derived [1,2]. These works show that a GRAPPA g-factor can be calculated directly from the GRAPPA weights, which corresponds with the g-factor familiar in SENSE reconstructions [3]. In this work, we extend this concept to GRAPPA acquisitions where m...