Linear and nonlinear photophysics and bioimaging of an integrin-targeting water-soluble fluorenyl probe.
نویسندگان
چکیده
Linear photophysical characterization and two-photon absorption (2PA) properties of a new water-soluble fluorene derivative, 3-(9-(2-(2-methoxyethoxy)ethyl)-2,7-bis{3-[2-(polyethyleneglycol-550-monomethylether-1-yl)]-4-(benzo[d]thiazol-2-yl)styryl}-9H-fluoren-9-yl)propanoic acid (1), were investigated in several organic solvents and water at room temperature. A comprehensive analysis of the steady-state absorption, emission and excitation anisotropy spectra revealed electronic structures of 1, including mutual orientation of the transition dipoles, relatively weak solvatochromic effects, high fluorescence quantum yield (approximately 0.5-1.0), and strong aggregation in water. The 2PA spectra of 1 were obtained in the 600-900 nm spectral range by two-photon induced fluorescence (2PF) and open aperture Z-scan methods using femtosecond laser sources. No discrete 2PA bands were apparent and values of the corresponding 2PA cross sections monotonically increased in the short wavelength range up to 3000 GM in organic solvents and approximately 6000 GM in aqueous solution, reflecting relatively high two-photon absorptivity. The 2PA efficiency of in water increased 2-3 times relative to aprotic solvents and can be explained by cooperative electronic effects of molecular aggregates of 1 produced in aqueous media. The carboxylic acid fluorenyl probe 1 was conjugated with the cyclic peptide RGDfK. Two-photon fluorescence microscopy (2PFM) imaging of U87MG cells (and MCF-7 as control), incubated with fluorene-RGD peptide conjugate 2, demonstrated high alpha(v)beta(3) integrin selectivity, making this probe particularly attractive for integrin imaging.
منابع مشابه
Folate receptor targeting silica nanoparticle probe for two-photon fluorescence bioimaging
Narrow dispersity organically modified silica nanoparticles (SiNPs), diameter ~30 nm, entrapping a hydrophobic two-photon absorbing fluorenyl dye, were synthesized by hydrolysis of triethoxyvinylsilane and (3-aminopropyl)triethoxysilane in the nonpolar core of Aerosol-OT micelles. The surface of the SiNPs were functionalized with folic acid, to specifically deliver the probe to folate receptor ...
متن کاملDesign, Synthesis and Biological Evaluation of Ketoprofen Conjugated To RGD/NGR for Targeted Cancer Therapy
It is well known that Arginine-Glycine-Aspartic acid (RGD) and Asparagine-Glycine-Arginine (NGR) peptides preferentially bind to integrin receptors and aminopeptidase Nrespectively and these two receptors play important roles in angiogenesis. Therefore ketoprofenas a non-selective cox Inhibitor was conjugated with linear RGD and NGR to take advantageof targeting capability of these two motifs a...
متن کاملDesign, Synthesis and Biological Evaluation of Ketoprofen Conjugated To RGD/NGR for Targeted Cancer Therapy
It is well known that Arginine-Glycine-Aspartic acid (RGD) and Asparagine-Glycine-Arginine (NGR) peptides preferentially bind to integrin receptors and aminopeptidase Nrespectively and these two receptors play important roles in angiogenesis. Therefore ketoprofenas a non-selective cox Inhibitor was conjugated with linear RGD and NGR to take advantageof targeting capability of these two motifs a...
متن کاملHighly emissive PEG-encapsulated conjugated polymer nanoparticles.
A novel bioimaging probe based on a conjugated polymer, poly(9,9-dihexylfluorene-alt-2,1,3-benzoxadiazole) (PFBD), is demonstrated. Transfer of the hydrophobic polymer into water using a short chain poly(ethylene glycol) (PEG) resulted in conjugated polymer nanoparticles (PEG-PFBD) with a fluorescence quantum yield of 46%. The PEG-PFBD nanoparticles possessed several desirable structural and ph...
متن کاملاندازهگیری ضریب شکست غیر خطی در شیشههای آلاییده به بلورهای نیمرسانا
There are several techniques in use for non-linear refractive index measurement, namely, interferometric techniques, in which conventional inter-ferometers are used, degenerate for wave mixing (DFWM), and z-scan, Each of these techniques suffers from some shortcmings. For example conventional interferometers like Fabry-Perot and Twyman-Green need high quality optical components, unwanted refl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Organic & biomolecular chemistry
دوره 8 11 شماره
صفحات -
تاریخ انتشار 2010