Pars and pedicle fracture and screw loosening associated with cortical bone trajectory: a case series and proposed mechanism through a cadaveric study.

نویسندگان

  • Wayne K Cheng
  • Yusuf T Akpolat
  • Serkan İnceoğlu
  • Shalin Patel
  • Olumide A Danisa
چکیده

BACKGROUND CONTEXT Cortical bone trajectory (CBT) technique for pedicle screw placement in the lumbar spine has become more popular since its introduction in 2009. The distinct advantages of using the CBT technique involve increased screw purchase within the cortical bone and reduced surgical dissection. However, contrary to several favorable biomechanical results, there were anecdotal reports of clinical complications associated with CBT. PURPOSE This study aimed (1) to report on two unique pars and pedicle fracture cases involving the use of the CBT technique and (2) to perform a cadaveric pilot study to determine the possible mechanism for this fracture pattern. STUDY DESIGN/SETTING A case report and cadaveric study were carried out. METHODS After presenting two clinical cases, 19 fresh-frozen lumbar vertebrae were obtained from 8 cadavers. Pedicle screws were instrumented on each level using CBT under video recording. After the instrumentation, X-ray images were obtained, and anatomical dissections were performed. RESULTS To be able to reach a necessary angle for medial to lateral CBT trajectory, 13 out of 19 (68%) spinous processes had to be removed. There were a total of seven complications. One pars and pedicle fracture out of 37 trajectories (2.7%) and 6 out of 37 trajectory deviations (16.2%), which resulted in gross loosening, were observed. CONCLUSIONS The head of the pedicle screw impinging on the base of spinous process and lamina was observed in our cadaveric model. This mechanism could potentially explain both screw loosening and fractures associated with the CBT technique.

منابع مشابه

Fatigue Performance of Cortical Bone Trajectory Screw Compared With Standard Trajectory Pedicle Screw.

STUDY DESIGN Cadaveric biomechanical study. OBJECTIVE To determine fatigue behavior of cortical bone trajectory (CBT) pedicle screws. SUMMARY OF BACKGROUND DATA Cortical bone trajectory screws have been becoming popular in spine surgery; however, the long-term fatigue behavior of the new CBT screws remains understudied and limitations not well defined. METHODS Twelve vertebrae from six ca...

متن کامل

The Cortical Bone Trajectory for Pedicle Screw Insertion.

P edicle screw fixation for spinal stabilization is now commonplace in spine surgery. Traditionally, pedicle screws are placed through a trajectory in which screw insertion utilizes a transpedicular path through the axis of the pedicle, either paralleling the end plate, as in the straightforward trajectory, or following the anatomic axis of the pedicle with an approximately 22° cephalocaudal tr...

متن کامل

Fixation Strength of Caudal Pedicle Screws after Posterior Lumbar Interbody Fusion with the Modified Cortical Bone Trajectory Screw Method

STUDY DESIGN Clinical case series. PURPOSE In the posterior lumbar interbody fusion (PLIF) procedure in our institute, the cephalad screw trajectory follows a mediolateral and caudocephalad directed path according to the original cortical bone trajectory (CBT) method. However, the starting point of the caudal screw is at the medial border of the pedicle on an articular surface of the superior...

متن کامل

Cortical bone trajectory for lumbar pedicle screws.

BACKGROUND CONTEXT Achieving solid implant fixation to osteoporotic bone presents a clinical challenge. New techniques and devices are being designed to increase screw-bone purchase of pedicle screws in the lumbar spine via a novel cortical bone trajectory that may improve holding screw strength and minimize loosening. Preliminary clinical evidence suggests that this new trajectory provides scr...

متن کامل

Review of Cortical Bone Trajectory: Evidence of a New Technique

This article summarizes recent evidence on the cortical bone trajectory (CBT) obtained from published anatomical, biomechanical, and clinical studies. CBT was proposed by Santoni in 2009 as a new trajectory that can improve the fixation of pedicle screws in response to screw loosening in osteoporotic patients. Recently, research interest has been growing with increasing numbers of published ser...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • The spine journal : official journal of the North American Spine Society

دوره 16 2  شماره 

صفحات  -

تاریخ انتشار 2016