Multishot EPI-SSFP in the heart.

نویسندگان

  • Daniel A Herzka
  • Peter Kellman
  • Anthony H Aletras
  • Michael A Guttman
  • Elliot R McVeigh
چکیده

Refocused steady-state free precession (SSFP), or fast imaging with steady precession (FISP or TrueFISP), has recently proven valuable for cardiac imaging because of its high signal-to-noise ratio (SNR) and excellent blood-myocardium contrast. In this study, various implementations of multiecho SSFP or EPI-SSFP for imaging in the heart are presented. EPI-SSFP has higher scan-time efficiency than single-echo SSFP, as two or more phase-encode lines are acquired per repetition time (TR) at the cost of a modest increase in TR. To minimize TR, a noninterleaved phase-encode order in conjunction with a phased-array ghost elimination (PAGE) technique was employed, removing the need for echo time shifting (ETS). The multishot implementation of EPI-SSFP was used to decrease the breath-hold duration for cine acquisitions or to increase the temporal or spatial resolution for a fixed breath-hold duration. The greatest gain in efficiency was obtained with the use of a three-echo acquisition. Image quality for cardiac cine applications using multishot EPI-SSFP was comparable to that of single-echo SSFP in terms of blood-myocardium contrast and contrast-to-noise ratio (CNR). The PAGE method considerably reduced flow artifacts due to both the inherent ghost suppression and the concomitant reduction in phase-encode blip size. The increased TR of multishot EPI-SSFP led to a reduced specific absorption rate (SAR) for a fixed RF flip angle, and allowed the use of a larger flip angle without increasing the SAR above the FDA-approved limits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multishot versus Single-Shot Pulse Sequences in Very High Field fMRI: A Comparison Using Retinotopic Mapping

High-resolution functional MRI is a leading application for very high field (7 Tesla) human MR imaging. Though higher field strengths promise improvements in signal-to-noise ratios (SNR) and BOLD contrast relative to fMRI at 3 Tesla, these benefits may be partially offset by accompanying increases in geometric distortion and other off-resonance effects. Such effects may be especially pronounced...

متن کامل

Two-dimensional multishot echo-planar coronary MR angiography.

This work presents a two-dimensional (2D) multishot echo-planar imaging (EPI) technique for magnetic resonance angiography (MRA) of individual coronary arteries in a 17-heartbeat breath-hold. Conventional 2D and 3D segmented gradient-echo (GRE) coronary MRA requires repetitive excitation of the same slice or slab within each cardiac cycle, which can result in reduced blood signal and in motion ...

متن کامل

Myocardial diffusion tensor imaging using diffusion-prepared SSFP

Background Diffusion tensor imaging of the myocardium is challenging due to the large bulk motion of the heart relative to the distance water diffuses. One solution is to use diffusion gradients on two consecutive heartbeats, with EPI to readout the stimulated echo [1]. The technique has not been widely adopted, primarily due to the long imaging times required to overcome the low SNR of the tec...

متن کامل

Multishot diffusion-weighted PROPELLER magnetic resonance imaging of the abdomen.

OBJECTIVE The objective of this study was to evaluate the feasibility of using multishot PROPELLER for diffusion-weighted imaging (DWI) of the abdomen. MATERIALS AND METHODS Diffusion-weighted abdominal imaging was performed in 9 healthy volunteers and 3 patients using both single-shot DW-SE-EPI and multishot DW-PROPELLER (BLADE sequence). We compared ADC measurements in phantoms, liver and p...

متن کامل

Characterizing physiological noise in the brainstem: passband SSFP vs. GRE-EPI

Introduction. Functional MRI of the brainstem is complicated by: 1) small grey matter nuclei, 2) severe distortions due to susceptibility boundaries and 3) high levels of physiological noise, all of which make conventional GRE-EPI BOLD problematic. SSFP fMRI has the potential to produce high-resolution images with reduced distortions [1-3], and recent work reported reduced physiological noise f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 47 4  شماره 

صفحات  -

تاریخ انتشار 2002