500 ml of blood loss does not decrease non-invasive tissue oxygen saturation (StO2) as measured by near infrared spectroscopy - A hypothesis generating pilot study in healthy adult women
نویسندگان
چکیده
BACKGROUND The goal when resuscitating trauma patients is to achieve adequate tissue perfusion. One parameter of tissue perfusion is tissue oxygen saturation (StO2), as measured by near infrared spectroscopy. Using a commercially available device, we investigated whether clinically relevant blood loss of 500 ml in healthy volunteers can be detected by changes in StO2 after a standardized ischemic event. METHODS We performed occlusion of the brachial artery for 3 minutes in 20 healthy female blood donors before and after blood donation. StO2 and total oxygenated tissue hemoglobin (O2Hb) were measured continuously at the thenar eminence. 10 healthy volunteers were assessed in the same way, to examine whether repeated vascular occlusion without blood donation exhibits time dependent effects. RESULTS Blood donation caused a substantial decrease in systolic blood pressure, but did not affect resting StO2 and O2Hb values. No changes were measured in the blood donor group in the reaction to the vascular occlusion test, but in the control group there was an increase in the O2Hb rate of recovery during the reperfusion phase. CONCLUSION StO2 measured at the thenar eminence seems to be insensitive to blood loss of 500 ml in this setting. Probably blood loss greater than this might lead to detectable changes guiding the treating physician. The exact cut off for detectable changes and the time effect on repeated vascular occlusion tests should be explored further. Until now no such data exist.
منابع مشابه
ml of blood loss does not decrease non - invasive tissue oxygen saturation ( StO 2 ) as measured by near infrared spectroscopy - A hypothesis generating pilot study in healthy adult
BACKGROUND: The goal when resuscitating trauma patients is to achieve adequate tissue perfusion. One parameter of tissue perfusion is tissue oxygen saturation (StO2), as measured by near infrared spectroscopy. Using a commercially available device, we investigated whether clinically relevant blood loss of 500 ml in healthy volunteers can be detected by changes in StO2 after a standardized ische...
متن کاملSimultaneous multi-depth assessment of tissue oxygen saturation in thenar and forearm using near-infrared spectroscopy during a simple cardiovascular challenge
INTRODUCTION Hypovolemia and hypovolemic shock are life-threatening conditions that occur in numerous clinical scenarios. Near-infrared spectroscopy (NIRS) has been widely explored, successfully and unsuccessfully, in an attempt to use it as an early detector of hypovolemia by measuring tissue oxygen saturation (StO2). In order to investigate the measurement site dependence and probe dependence...
متن کاملNear-infrared spectroscopy technique to evaluate the effects of red blood cell transfusion on tissue oxygenation
INTRODUCTION The aim of this study was to evaluate the effects of red blood cell (RBC) transfusions on muscle tissue oxygenation, oxygen metabolism and microvascular reactivity in critically ill patients using near-infrared spectroscopy (NIRS) technology. METHODS This prospective, observational study included 44 consecutive patients hospitalized in the 31-bed, medical-surgical intensive care ...
متن کاملBedside monitoring of patients with shock using a portable spatially-resolved near-infrared spectroscopy.
Clinical monitoring of shock mainly depends on blood-oxygen-indices obtained from invasive blood sample tests. The central internal jugular central vein oxygenation level (ScvO2) has been considered as a gold standard indicator for shock prediction. We developed a noninvasive spatially-resolved near-infrared spectroscopy (SR-NIRS) to measure tissue blood oxygen saturation (StO2) surrounding the...
متن کاملMonitoring tissue blood oxygen saturation in the internal jugular venous area using near infrared spectroscopy.
Central venous blood oxygen saturation (ScvO2) is an important monitoring index of fluid resuscitation. However, monitoring of ScvO2 is not continuous and invasive. Near infrared spectroscopy (NIRS) is an optical technology for the noninvasive detection of hemodynamic changes, with advantages of being real-time, continuous, low-cost, and portable. The present study aimed to determine whether a ...
متن کامل