CT colonography: A new technique for colorectal cancer screening

نویسنده

  • Michael E. Pezim
چکیده

Although optical col on oscopy is the criterion standard for colorectal cancer screening, CT colonography is now accepted to be useful when screening averagerisk patients. Earlier studies that indicated poor sensitivity for CT colonography have now been largely refuted. Recent improvements in workstation design and advances that permit primary 3D viewing of images have increas ed screening accuracy. Access to CT colonography is still somewhat limited, but some advantages of CT colonography over optical co lonoscopy in clude the lack of side effects from sedation and low per foration rates. Disadvantages of screening with CT colonography include the need to schedule a subsequent optical colonoscopy if images indicate a biopsy or polypectomy is required, and the reduced ability of CT co lonography to identify small polyps which rarely, but occasionally, are significant. C olorectal cancer (CRC) is the third most common malignancy in Canada and the number one cause of cancer death among nonsmokers in North America. The incidence in creases significantly after age 50. More than 700 people die of CRC annually in BC alone, each losing an estimated 10 years of productive life, for a total yearly provincial loss of over 7000 productive years. Threequarters of all CRC occurs in asymptomatic average-risk individuals, that is, patients older than 50, without a family history of the disease, and with no other risk factors such as inflammatory bowel disease or familial polyposis. CRC: The ideal disease for screening Because CRC exists initially as premalignant polyps in virtually all cases, and because early CRC is more curable than late CRC (90% cure rates when patient is asymptomatic vs 50% cure rates when patient is symptomatic), this disease is ideally suited for a screening program. However, two Canadian studies have shown very poor compliance rates for CRC screening. A study by Rabeneck and Paszat of nearly 1 million screeneligible Ontario patients age 50 to 59 determined that fewer than 20.5% had undergone any form of CRC screening during a 6-year follow-up period. A more recent phone survey of 1808 Alberta men and women between age 50 and 74 determined that only 13.2% of these average-risk patients had been advised by a physician to undergo CRC screening and only 3% had undergone endoscopy within the past 5 years, despite the fact that screening for CRC is supported by both the Canadian Cancer Society and the American Cancer Society. Multiple procedures for CRC screening are available, including digital rectal examination, fecal occult blood testing, double-contrast barium enema, and flexible sigmoidoscopy. CT colonography: A new technique for colorectal cancer screening Average-risk patients may be candidates for a less invasive imaging technology. Borys Flak, MD, FRCPC, Bruce B. Forster, MD, FRCPC, Michael E. Pezim, MD, FRCSC, FACS Dr Flak provides professional services on a contract basis to Canadian Diagnostic Centres, where CT colonography studies are performed for screening purposes. Dr Forster is an associate professor and vicechairman of research in the Department of Radiology at the University of British Columbia, and medical director of Canada Diagnostic Centres (BC). Dr Pezim is the medical director of the Pezim Clinic, a colorectal diagnostic centre in Vancouver, and a coauthor of The Intelligent Patient Guide to Colorectal Cancer. 206 BC MEDICAL JOURNAL VOL. 50 NO. 4, MAY 2008 of resorption, and thus diminishes patient discomfort. Optimal colon preparation and distention is absolutely vital to ensure an adequate study. Inadequate prep and colonic distention are the most common causes of false-negative examinations. The patient is scanned in both the supine and prone positions. In problem cases, the decubitus position may be used as well. These maneuvers improve the probability of adequately distending all colonic segments, shift any residual fluid from segment to segment (unmasking polyps that may be hidden within a fluid column), and help to differentiate stool, which tends to be mobile, from polyps, which remain static. Intravenous contrast is not generally used for CTC examinations as it is not felt that the increased but still very small risk associated with possible contrast reactions is justified in the well-prepped colon. Spasmolytics are also not routinely utilized as several studies have shown them to be of little value. A Toshiba 64 multislice scanner is used by the authors. Scans are acquired at 0.5 mm resolution and reconstructed at 2 mm collimation at 25 to 30 mAs and 120 kVp. Such thin slices are required to diminish volume averaging and improve multiplanar reformats and 3D reconstructions, thus optimizing sensitivity for detection of CT colonography: A new technique for colorectal cancer screening Figure 1. 2D view from CTC. Image obtained with patient in the prone position. Colonic fluid appears white because of prep with Telepaque (arrowhead). Polyp (long arrow) is shown as a soft tissue mass outlined by a thin rim of contrast. Rectal tube with inflatable balloon is also visible (short white arrow). Image courtesy of Dr Perry Pickhardt Other procedures on the horizon include video colon capsules and DNA testing. However, at present optical colonoscopy (OC) remains the criterion standard and should be used when assessing any new techniques. One such technique, CT colonography (CTC), is now accepted to have an important role to play in screening average-risk patients. At present, ac cess to CTC is still somewhat limited, although there are now a number of public imaging facilities providing the service in BC. Any local populationbased impact on CRC screening, however, is likely to be some years away. CT colonography CT colonography was first introduced by Vining and Gelfand in 1994. CTC is now the preferred name, although “virtual colonoscopy” is also commonly used. Since its introduction, CTC has benefited immensely from technological improvements such as multidetector CT scanners and im proved workstations. At present an optimal CTC examination still re quires a bowel cleansing regimen identical to that used for colonoscopy, with the addition of dilute barium and a cholecystographic agent (e.g., Telepaque) taken orally. Barium, by becoming incorporated into any remaining stool, helps differentiate polyps from stool. Telepaque, by increasing the density of any residual colonic fluid, helps reveal polyps that otherwise may remain isodense within fluid and not be visualized. Other means of “tagging” stool in concert with advanced image processing techniques may mean that in future less or no colonic preparation will be required. The CTC procedure begins when a rectal tube is inserted and the colon is insufflated manually with carbon dioxide, which is preferred to room air because it has a much greater rate 207 VOL. 50 NO. 4, MAY 2008 BC MEDICAL JOURNAL smaller polyps. This technique results in an estimated effective radiation dose of 5.9 mSv, which compares with annual background radiation of 2.3 mSv in the Lower Mainland and a dose from a double-contrast barium enema of 4 to 8 mSv. A reasonable rule of thumb for considering radiation risk is that for every 10 mSv of exposure, a patient has a 1 in 1000 lifetime risk of developing cancer. This statistic compares with an annual risk of mortality in a motor vehicle accident in the US of 1 in 5900, and the natural incidence of fatal cancer, which is 230 in 1000. As any potential cancer induction takes many years, the risk obviously diminishes with age, and screening for average-risk subjects is only recommended for patients older than 50. There has been some controversy in the radiology literature regarding which method of primary reading of CTC studies, 2D or 3D, is the most accurate and efficient. Initially, workstations and CT scanners were less so phisticated and most radiologists were more comfortable scrolling through the images—that is, reading in 2D and referring to 3D images in problem areas. This method is tedious and time-consuming. Pickhardt’s landmark study was the first to utilize primary 3D read and report excellent accuracy. Using a revolutionary workstation that enabled user-friendly automated fly-through luminal navigation, Pickhardt made a strong case for primary 3D read. Radiologists will vary in their approach, based on their own experience and what equipment is available to them. The authors use the Viatronix workstation that Pickhardt used and a combination of 2D and 3D viewing, but rely on primary 3D interpretation. An example of a CTC study with a comparison colonoscopy image is shown in . CT colonography versus standard optical colonoscopy There is a steep learning curve when using either CTC or OC technology. For CTC, meticulous attention to technique, adequate time for careful analysis, and up-to-date equipment are crucial to the production of acceptable results. For OC, careful training and a dedication to absolute patient safety are needed to ensure accurate results and a safe and comfortable patient experience. OC has very high sensitivity and specificity, making it the criterion standard for colorectal examination. In addition, OC images can often be used to distinguish between hyperplastic and adenomatous polyps on the basis of appearance or with the use of fluorescence imaging, and OC has the significant advantage of permitting immediate biopsy, polypectomy, or both if required. The procedure is not perfect and lesions can be missed. Reports show miss rates of 26% to 27% for polyps less than 5 mm, 13% for polyps 6 to 9 mm, and 2% to 6% for polyps greater than 10 mm. Overall OC is felt to have an accuracy of approximately 97%. It does suffer from a less than 100% completion rate, although incompletion rates are very low in the hands of expert co lonoscopists with the availability of double-balloon variable-stiffness adult and pediatric colonoscopes. Risk of Figures 1, 2 and 3 CT colonography: A new technique for colorectal cancer screening Image courtesy of Dr Perry Pickhardt Figure 2. 3D view from CTC. Image shows the same polyp (arrow) revealed in 2D view and is very similar to the image obtained by OC shown in Figure 3. 208 BC MEDICAL JOURNAL VOL. 50 NO. 4, MAY 2008 same size. Disparities may be related to differences in experience and the quality of equipment used by these two research groups. In line with Pickhardt’s results, several recent large studies have provided further strong evidence that CTC is capable of high accuracy. Unpublished and preliminary re sults from the NIH-funded American College of Radiology Imaging Network (ACRIN) study were presented by Dr Johnson at this fall’s ACRIN meeting. The study involved 2531 patients in 15 US centres who had OC and CTC on the same day. The sensitivity and specificity statistics from the study include a 90% per patient sensitivity for polyps greater than 10 mm—on par with OC sensitivity. This study also reported very high negative predictive value percentages, which are vital for an effective screening study. A second large study published recently by Kim compared primary CTC in 3120 consecutive adults (mean age 57) with primary OC in 3163 consecutive adults (mean age 58). The results shown in the include the finding that only 246 CTC patients (7.9%) needed to be referred for OC. Other relevant findings from this study include the fact that only 20 polyps less than 10 mm were histologically advanced in 15 patients (a rate of 0.2%). Also, only three patients with a total of four polyps less than Table CT colonography: A new technique for colorectal cancer screening Figure 3. 3D view from OC. Image obtained by OC of the same polyp (arrow) shown in Figures 1 and 2. Image courtesy of Dr Perry Pickhardt perforation is rare in experienced hands, ranging from 0.016% to 0.22%. Intravenous sedation is generally used for colonoscopy. Sedation complications are extremely rare. Most patients tolerate the procedure well and find the colon preparation to have been more of a challenge than the actual procedure. Colonoscopy has the additional advantage of zero radiation. CTC does not require sedation, eliminating the need for an intravenous line, the potential side effects of sedation, and the need for monitoring. This allows patients to be released unaccompanied immediately following the procedure and to return to normal activity, including driving an automobile. Comparing the level of patient comfort during the two examinations is difficult as OC patients are sedated and typically have little recollection of the study. Perforation rates during CTC are even lower than during OC. Inability to complete a CTC study is also rare, although a poorly distensible segment of colon may hamper CTC interpretation. Such segments may require endoscopic assessment. An advantage of CTC over OC is its ability to detect significant extracolonic findings. For example, CTC can identify renal cell carcinomas (4%), abdominal aortic aneurysms (5%), and lymphadenopathy (6%). The evaluation of solid organs in the abdomen is limited when compared with a standard contrast-enhanced CT scan because of the nonintravenous nature of contrast agents and low-dose radiation protocols used in CTC. Studies comparing the accuracy of CTC and OC have previously shown widely varying results. Cotton, an en doscopist, found a sensitivity of only 55% for polyps greater than 10 mm and 39% for polyps greater than 6 mm, whereas Pickhardt, a radiologist, reported sensitivities of 93.8% and 88.7%, respectively, for polyps of the 209 VOL. 50 NO. 4, MAY 2008 BC MEDICAL JOURNAL 10 mm had high-grade dysplasia (a rate of 0.05%) and no subcentimetre cancers were found. The authors concluded that “CTC and OC screening methods resulted in similar detection rates for advanced neoplasms within the same general population.” The primary CTC group underwent fewer optical colonoscopies and polypectomies, suggesting that CTC might be used effectively as a screening filter for therapeutic OC. Perhaps such a combined approach would result in greater overall compliance for CRC screening. Looking ahead Of the imaging technologies used to view the entire colorectum, optical colonoscopy is still considered the criterion standard. However, when screening average-risk patients for CRC, CT colonography should be considered. Earlier studies that showed poor sensitivity for CTC have now been largely refuted. Assuming there is state-of-the-art equipment and technical expertise in performing and in terpreting the studies, CTC has high sensitivity. The primary methodological issue that has prevented endoscopists from fully embracing CTC is based on the assumption that polyps less than 5 to 6 mm require biopsy or excision because advanced neoplasms may occasionally be small. Nevertheless, the extremely low prevalence of advanced neoplasia or frank carcinoma in these small lesions may justify CTC management and permit following these patients with a repeat examination on a more frequent schedule and checking for interval increase in size. As of March 2008, the American Cancer Society has added CTC to its list of acceptable front-line screening modalities. Future developments in CTC will include even more sophisticated and user-friendly workstation tools, which will reduce interpretation times and allow the incorporation of computeraided diagnosis as a primary review to identify suspicious areas for the radiologist to reconcile. Advances will also permit less vigorous colon cleansing. Already some studies show promise for CTC with unprepared colons. Advances on the horizon for OC in clude increasingly sophisticated light refraction systems that can identify areas of dysplasia not previously visible, wider angle lenses permitting greater view around folds to improve accuracy, instruments that will “walk” into the colon on their own motorized legs and negotiate colonic angulations more easily, and further improvements in analgesia to eliminate patient discomfort. As well as improving the accuracy of both OC and CTC images, it is hoped that these developments will improve the currently poor screening rates in BC and Canada for a prevalent and deadly cancer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Efficacy of CT colonography versus colonoscopy in screening for colorectal cancer].

OBJECTIVE To determine the efficacy and effectiveness of CT colonography in comparison with those of colonoscopy in screening for colorectal cancer. MATERIAL AND METHODS We systematically reviewed all the studies in the scientific literature that assessed the efficacy of CT colonography in screening for colorectal cancer. We excluded articles that assessed the efficacy of other screening tech...

متن کامل

Cost-effectiveness of computerized tomographic colonography versus colonoscopy for colorectal cancer screening.

BACKGROUND Computerized tomographic (CT) colonography is a potential alternative to colonoscopy for colorectal cancer screening. Its main advantage, a better safety profile, may be offset by its limitations: lower sensitivity, need for colonoscopy in cases where results are positive, and expense. METHODS We performed an economic evaluation, using decision analysis, to compare CT colonography ...

متن کامل

CT colonography (virtual colonoscopy): technique, indications and performance.

Worldwide, colorectal cancer is the third most frequent cancer occurring in both sexes. Screening programs for early detection enable detection of tumors at an earlier stage and have been shown to reduce death rate. Currently, colonoscopy is the investigation of choice for colorectal cancer screening and for investigation of patients with suspected colorectal cancer. However, colonoscopy remain...

متن کامل

Advances in CT Colonography for Colorectal Cancer Screening and Diagnosis

CT colonography (CTC) is a validated colorectal cancer test that provides an additional minimally-invasive screening option which is likely to be preferred by some patients. Important examination prerequisites include adequate colonic cleansing and distention. Tagging of residual material aids in the differentiation of true polyps from stool. Low radiation dose technique should be employed rout...

متن کامل

Evolution of CT colonography REVIEW

Many public health organizations, including the American Cancer Society, recommend colorectal carcinoma screening for all average risk adults beginning at the age of 50 years. Colorectal cancers are known to develop from precursor adenomatous polyps that progress from small to large size and from dysplasia to cancer over the course of many years. Despite the potential for prevention, patient co...

متن کامل

Colorectal cancer screening with CT colonography, colonoscopy, and double-contrast barium enema examination: prospective assessment of patient perceptions and preferences.

PURPOSE To prospectively assess and compare perceptions of and preferences for computed tomographic (CT) colonography, colonoscopy, and double-contrast barium enema examination (DCBE) by asymptomatic patients undergoing colorectal cancer screening. MATERIALS AND METHODS A total of 696 asymptomatic patients at higher-than-average risk undergoing colorectal cancer screening were consecutively r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008