Identification of high explosives using single-particle aerosol mass spectrometry.
نویسندگان
چکیده
The application of single-particle aerosol mass spectrometry (SPAMS) to the real-time detection of micrometer-sized single particles of high explosives is described. Dual-polarity time-of-flight mass spectra from 1000 single particles each of 2,4,6-trinitrotoluene (TNT), 1,3,5-trinitro-1,3,5-triazinane (RDX), and pentaerythritol tetranitrate (PETN), as well as those of complex explosives, Composition B, Semtex 1A, and Semtex 1H, were obtained over a range of desorption/ionization laser fluences between 0.50 and 8.01 nJ/microm2. Mass spectral variability with laser fluence for each explosive is discussed. The ability of the SPAMS system to identify explosive components in a single complex explosive particle ( approximately 1 pg) without the need for consumables is demonstrated.
منابع مشابه
Improved identification of primary biological aerosol particles using single-particle mass spectrometry
Measurements of primary biological aerosol particles (PBAP), especially at altitudes relevant to cloud formation, are scarce. Single-particle mass spectrometry (SPMS) has been used to probe aerosol chemical composition from ground and aircraft for over 20 years. Here we develop a method for identifying bioaerosols (PBAP and particles containing fragments of PBAP as part of an internal mixture) ...
متن کاملSingle particle analysis of soil dust by aerosol time-of-flight laser mass spectrometry
A laboratory study was carried out to investigate the single particle soil dust using aerosol time-of-flight mass spectrometry. The presence of crustal elements is observed in the mass spectra of individual particles. Potassium and iron constitute the two most commonly detected cations. Other common cations observed in the mass spectra of soil particles include sodium and magnesium. According t...
متن کاملDetermination of inorganic improvised explosive device signatures using laser electrospray mass spectrometry detection with offline classification.
The mass spectral detection of low vapor pressure, inorganic-based explosive signatures including ammonium nitrate, chlorate, perchlorate, sugar, and the constituents contained within black powder are reported using laser electrospray mass spectrometry. The ambient pressure mass spectrometry technique combining nonresonant, femtosecond laser vaporization with electrospray postionization reveale...
متن کاملSignal Variation in Single Particle Aerosol Mass Spectrometry by Zachary Daniel Wissner
Rapid and accurate detection of airborne micro-particles is currently an important problem in national security. One approach to such detection, bioaerosol mass spectrometry (BAMS), is currently under development at Lawrence Livermore National Laboratory. BAMS is a type of single particle aerosol mass spectrometry that rapidly records dual-polarity mass spectra of aerosolized micro-particles. H...
متن کاملInteractive comment on “Improved identification
In their manuscript “Improved identification of primary biological aerosol particles using single particle mass spectrometry”, Zawadowicz et al. present a new classification method to distinguish single particles containing “biological” and “inorganic” phosphorus from their mass spectra. The algorithm is developed and tested using single particle mass spectra acquired in laboratory measurements...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 79 5 شماره
صفحات -
تاریخ انتشار 2007