The objective of the present study was to compare single segment and double segment INTACS rings in the treatment of post-LASIK ectasia. In this interventional study, 26 eyes with post-LASIK ectasia were assessed. Ectasia was defined as progressive myopia regardless of astigmatism, along with topographic evidence of inferior steepening of the cornea after LASIK. We excluded those with a history of intraocular surgery, certain eye conditions, and immune disorders, as well as monocular, pregnant and lactating patients. A total of 11 eyes had double ring and 15 eyes had single ring implantation. Visual and refractive outcomes were compared with preoperative values based on the number of implanted INTACS rings. Pre and postoperative spherical equivalent were -3.92 and -2.29 diopter (P=0.007). The spherical equivalent decreased by 1 ± 3.2 diopter in the single-segment group and 2.56 ± 1.58 diopter in the double-segment group (P=0.165). Mean preoperative astigmatism was 2.38 ± 1.93 diopter which decreased to 2.14 ± 1.1 diopter after surgery (P=0.508); 0.87 ± 1.98 diopter decrease in the single-segment group and 0.67 ± 1.2 diopter increase in the double-segment group (P=0.025). Nineteen patients (75%) gained one or two lines, and only three, who were all in the double-segment group, lost one or two lines of best corrected visual acuity. The spherical equivalent and vision significantly decreased in all patients. In these post-LASIK ectasia patients, the spherical equivalent was corrected better with two segments compared to single segment implantation; nonetheless, the level of astigmatism in the single-segment group was significantly better than that in the double-segment group.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of single-segment and double-segment Intacs for keratoconus and post-LASIK ectasia.

PURPOSE To evaluate the efficacy of single-segment Intacs and compare with double-segment Intacs in subjects with post-LASIK ectasia and keratoconus. DESIGN Retrospective comparative analysis. METHODS setting: Boxer Wachler Vision Institute, Beverly Hills, California, USA. study population: Thirty-seven eyes of 28 patients with keratoconus and post-LASIK ectasia classified into two groups: ...

متن کامل

Management of post-LASIK corneal ectasia with Intacs inserts: one-year results.

OBJECTIVE To prospectively study the effects of the use of Intacs microthin prescription inserts (Addition Technology Inc, Fremont, Calif) for the postoperative management of corneal ectasia resulting from laser in situ keratomileusis (LASIK). METHODS In this prospective nonrandomized clinical trial, 10 eyes of 7 patients with post-LASIK corneal ectasia (2 men and 5 women) aged 33 to 46 years...

متن کامل

New surgical approaches to the management of keratoconus and post-LASIK ectasia.

PURPOSE The objective of this study is to describe the authors' results with intrastromal corneal ring segments (Intacs) and a new variation of lamellar keratoplasty, termed intralamellar keratoplasty (ILK), for the treatment of keratoconus (KCN) and post-laser-assisted in situ keratomileusis (LASIK) ectasia. METHODS A retrospective review of contact lens-intolerant KCN and post-LASIK ectasia...

متن کامل

Post-LASIK ectasia treated with intrastromal corneal ring segments and corneal crosslinking.

Corneal ectasia is a serious complication of laser in situ keratomileusis (LASIK). We report the case of a 29-year-old man who underwent LASIK in both eyes and in whom corneal ectasia developed in the left eye 3 years after surgery. He was treated sequentially with intraocular pressure-lowering medication, intrastromal corneal ring segment (ICRS) implants, and collagen cross-linking. Vision imp...

متن کامل

Management of corneal ectasia after laser in situ keratomileusis with INTACS.

PURPOSE To evaluate the safety and efficacy of intrastromal corneal ring segments (ICRS, INTACS, Keravision) for the correction of corneal ectasia after laser in situ keratomileusis (LASIK). METHODS In this prospective, noncomparative case series, INTACS were implanted in three eyes (two patients) that were ectatic after LASIK. Mean follow-up was 8.7 months (range, 8 to 10 mo). RESULTS No i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta medica Iranica

دوره 52 9  شماره 

صفحات  -

تاریخ انتشار 2014