Issues in Using Human Variability Distributions to Estimate Low-Dose Risk

نویسندگان

  • Kenny S. Crump
  • Weihsueh A. Chiu
  • Ravi P. Subramaniam
چکیده

BACKGROUND The National Research Council (NRC) Committee on Improving Risk Analysis Approaches Used by the U.S. EPA (Environmental Protection Agency) recommended that low-dose risks be estimated in some situations using human variability distributions (HVDs). HVD modeling estimates log-normal distributions from data on pharmacokinetic and pharmacodynamic variables that affect individual sensitivities to the toxic response. These distributions are combined into an overall log-normal distribution for the threshold dose (dose below which there is no contribution to a toxic response) by assuming the variables act independently and multiplicatively. This distribution is centered at a point-of-departure dose that is usually estimated from animal data. The resulting log-normal distribution is used to quantify low-dose risk. OBJECTIVE We examined the implications of various assumptions in HVD modeling for estimating low-dose risk. METHODS The assumptions and data used in HVD modeling were subjected to rigorous scrutiny. RESULTS We found that the assumption that the variables affecting human sensitivity vary log normally is not scientifically defensible. Other distributions that are equally consistent with the data provide very different estimates of low-dose risk. HVD modeling can also involve an assumption that a threshold dose defined by dichotomizing a continuous apical response has a log-normal distribution. This assumption is shown to be incompatible (except under highly specialized conditions) with assuming that the continuous apical response itself is log normal. However, the two assumptions can lead to very different estimates of low-dose risk. The assumption in HVD modeling that the threshold dose can be expressed as a function of a product of independent variables lacks phenomenological support. We provide an example that shows that this assumption is generally invalid. CONCLUSION In view of these problems, we recommend caution in the use of HVD modeling as a general approach to estimating low-dose risks from human exposures to toxic chemicals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DEVELOPMENT OF A PHYSIOLOGICALLY BASED TOXICOKINETIC MODEL FOR HUMAN EXPOSURE RISK ASSESSMENT OF METHYLENE DIPHENYL DIISOCYANATE(MDI)

Introduction: Given the lack of a developed physiologically based toxicokinetic (PBTK) model for human systemic exposure assessment of methylene diisocyanate (MDI) and prediction of its urinary metabolites, this study aims to develop a PBTK model for exposure risk assessment of MDI. Methods and Materials: In this study, to assess the potential exposure to the MDI, a PBTK model was constructed ...

متن کامل

The comparison of serial SPECT-CT imaging to estimate absorbed dose to the organ at risk from peptide receptor radionuclide therapy dosimetry

Introduction: In Peptide Receptor Radionuclide Therapy (PRRT), the administration of radionuclide such as Lu-177 label with a pharmaceutical agent useful to destroy the lesion. The amount of Lu-177 radioactivity administered to the patients is still not standardize and generally not more than 7.4 GBq per session due to the patient’s safety issues. The first cycle of Lu-177 is a...

متن کامل

Dose response evaluation of a low density anoxic polymer gel dosimeter using MRI

Background: The human body contains of different tissues and cavities with different physical and radiological properties. Most important among these are tissues and cavities that are radiologically different from water, including lungs, sinuses and bones. Gel dosimetry provides a unique feature to display dose distributions occurring in clinical radiation therapy in three dimensions. Materials...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Radiation cancer risk from doses to newborn infants hospitalized in neonatal intensive care units in children hospitals of Isfahan province

Background: This study aimed to investigate dose area product (DAP), effective dose, and radiation risk in newborn infants hospitalized in neonatal intensive care units in Isfahan and Kashan. Materials and Methods: During a period of six months, DAP for chest X-ray examinations for newborn infants hospitalized in NICUs of five special hospitals including Beheshti (in Kashan), Al-Zahra, Imam Hos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 118  شماره 

صفحات  -

تاریخ انتشار 2010