Mass Spectroscopy Using Single Ion Cyclotron Resonance

نویسندگان

  • George Koster
  • David E. Pritchard
چکیده

An inhomogeneous radio fquency electric field can couple the cyclotron and axid modes of a single icn in a Penning trap. The classical equations of motion are the same as those of a driven quantum mechanical two-level system. We discuss an analog of the A-pulse, which can exchange mode actions, and an analog of avoided crossing. Experimental illustrations are presented. PACS: 07.75.+h, 46.10.+z, 41.70.+t, 32.90.+a Submitted to Phys. Rev. A In experiments to perform precise resonance measurements on single charged particles in a Penning trap[VSD87,VMF88,CWB89], only one of the particle's normal mode motions is typically detected directly. For example, in our recent single ion cyclotron resonance experiment[CWB89,WLB88], only the axial mode couples to our detector. The cyclotron and the magnetron modes are undetected and essentially undamped. Cooling, driving and measuring the frequency of the undetected modes require techniques for coupling them to the detected mode. Wineland and Dehmelt[WID75] suggested that an inhomogeneous rf electric field at the sum or difference frequency of two modes will couple those modes, and that in particular the magnetron mode can be cooled by coupling it to the damped axial mode. The technique was demonstrated experimentally by Van Dyck, Schwinberg, and RQG DehmeltwSD78], Cohen-Tannoudji[COH84] and Brown and Gabrielse[86] discuss rf coupling fields in some generality and kgor. In this paper we develop two particular effects of such coupling fields, using an analogy with a two-state quantum mechanical system to motivate our purely classical results. The data which we present here were taken on an apparatus designed to compare the cycl~aon frequencies of single ions with the eventual goal of measuring ion mass ratios to parts in lo1*. The apparatus, an orthogonally compersated [GAB85], hyperbolic Penning trap in a cryogenic environment is described in references [ C W 8 9 and

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Towards analytically useful two-dimensional Fourier transform ion cyclotron resonance mass spectrometry.

Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) achieves high resolution and mass accuracy, allowing the identification of the raw chemical formulae of ions in complex samples. Using ion isolation and fragmentation (MS/MS), we can obtain more structural information, but MS/MS is time- and sample-consuming because each ion must be isolated before fragmentation. In 1987,...

متن کامل

The Preparation, Characterization and Tribological Properties of TA-C:H Deposited Using an Electron Cyclotron Wave Resonance Plasma Beam Source

A compact electron cyclotron wave resonance (ECWR) source has been developed for the high rate deposition of hydrogenated tetrahedral amorphous carbon (ta-C : H). The ECWR provides growth rates of up to 900 AÊ /min over a 400 diameter and an independent control of the deposition rate and ion energy. The ta-C : H was deposited using acetylene as the source gas and was characterized in terms of i...

متن کامل

Characterization of nitrogen compounds in coker gas oil by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry and Fourier transform infrared spectroscopy

In this study, the classes and structures of nitrogen species in coker gas oil (CGO) are characterized by electrospray ionization (ESI) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) combined with Fourier transform infrared (FT-IR) spectroscopy. The results demonstrate that the m/z of basic and non-basic nitrogen compounds ranges from 180 to 560 and from 200 to 460, res...

متن کامل

Dissociation of heme from gaseous myoglobin ions studied by infrared multiphoton dissociation spectroscopy and Fourier-transform ion cyclotron resonance mass spectrometry.

Detachment of heme prosthetic groups from gaseous myoglobin ions has been studied by collision-induced dissociation and infrared multiphoton dissociation in combination with Fourier-transform ion cyclotron resonance mass spectrometry. Multiply charged holomyoglobin ions (hMbn+) were generated by electrospray ionization and transferred to an ion cyclotron resonance cell, where the ions of intere...

متن کامل

Pulsed electromagnetic field at frequency and intensity resembling potassium ion cyclotron resonance selectively impairs breast cancer cell through apoptosis

Introduction: Breast cancer (BC) is the most common women cancer worldwide. Radiotherapy and chemotherapy are the two common treatment options but these techniques suffer low selectivity and adverse effects on surrounding normal tissues. Non- ionizing pulsed electromagnetic fields (PEMFs) in ultra-narrow band frequency and intensity have shown anticancer effects. Changing potas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005