Validation of measurements of mandibular protrusion in the treatment of obstructive sleep apnoea and snoring with a mandibular protruding device.
نویسندگان
چکیده
The aims of this study were to compare the maximum range of protrusion determined with a ruler with measurements made using a George Gauge (GG) and to validate the methods of measurement (ruler and GG) of the advancement established by mandibular protruding devices (MPDs), using cephalograms as the gold standard. The study comprised 77 patients (63 males, 14 females, mean age 54 years, range 31-73 years) with obstructive sleep apnoea (OSA) (n = 50) or complaints of snoring (n = 27). After a medical examination that included an overnight somnographic registration and a dental and stomatognathic examination, each patient was given a MPD. Measurements of the maximum range of protrusion with the GG and a ruler were compared. Pairs of upright cephalograms were taken with and without the MPD. The position of the mandible on the cephalograms was compared with ruler measurements of the device-induced protrusion in the incisor and premolar regions, the vertical opening in the anterior region, and GG construction bite registration. The maximum range of protrusion was significantly greater with GG than ruler measurements, on average +1.2 mm (P < 0.001). The mandibular position as measured in the incisor or premolar region with a ruler or on the cephalogram was not significantly different. GG values, however, were higher and differed significantly from ruler and cephalometric measurements (P < 0.001). The degree of anterior mandibular advancement with a MPD measured with a ruler in the incisor or premolar regions compared well with corresponding cephalometric measurements. The ruler and cephalometric measurements of the vertical opening with the MPD coincided well in the incisor region. The GG overestimated the maximum range of protrusion compared with ruler measurements.
منابع مشابه
Sleep nasendoscopy: a diagnostic tool for predicting treatment success with mandibular advancement splints in obstructive sleep apnoea.
This prospective, cohort study evaluated the role of sleep nasendoscopy (SNE) with simultaneous mandibular protrusion in predicting successful mandibular advancement splint (MAS) therapy in subjects with obstructive sleep apnoea (OSA). Nineteen OSA subjects diagnosed by overnight polysomnography were referred for MAS therapy, following SNE investigation. A Herbst MAS was fabricated for each sub...
متن کاملSleep disordered breathing.
A randomized, controlled study of a mandibular advancement splint for obstructive sleep apnea. Efficacy of positive airway pressure and oral appliance in mild to moderate obstructive sleep apnea. advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success. Assessment of upper airway dynamics in awake sleep apnea patients wi...
متن کاملSleep-disordered breathing.
A randomized, controlled study of a mandibular advancement splint for obstructive sleep apnea. Efficacy of positive airway pressure and oral appliance in mild to moderate obstructive sleep apnea. advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success. Assessment of upper airway dynamics in awake sleep apnea patients wi...
متن کاملDetection of right ventricular dysfunction by tissue Doppler imaging in asymptomatic patients with pulmonary sarcoidosis.
snoring and obstructive sleep apnea: a review. Sleep 2006; 29: 244–262. 3 Tsuiki S, Kobayashi M, Namba K, et al. Optimal positive airway pressure predicts oral appliance treatment response to sleep apnoea. Eur Respir J 2010; 35: 1098–1105. 4 Isono S. Upper airway muscle function during sleep. In: Loughlin GM, Varroll JL, Marcus CI, eds. Sleep and Breathing in Children. New York, Marcel Dekker, ...
متن کاملMandibular advancement and obstructive sleep apnoea: a method for determining effective mandibular protrusion.
The objectives of the study were to test the hypotheses that it is possible, during routine polysomnography (PSG), to prospectively identify favourable candidates for mandibular repositioning appliance (MRA) therapy in the treatment of obstructive sleep apnoea (OSA) and to accurately estimate an optimal protrusive distance at which to fabricate the MRA. A series of subjects underwent a remotely...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of orthodontics
دوره 25 4 شماره
صفحات -
تاریخ انتشار 2003