Detection of subependymal veins using high-resolution magnetic resonance venography.

نویسندگان

  • M Ohkawa
  • N Fujiwara
  • T Katoh
  • Y Mori
  • S Nakano
  • M Tanabe
  • Y Honjo
  • S Nagao
چکیده

High-resolution magnetic resonance venography (HR-MRV) of intracranial subependymal veins using a two-dimensional Fourier-transform time-of-flight technique was performed on normal volunteers and clinical cases of cerebral disease. For the pulse sequence, fast-field-echo sequence was used with the following parameters: TR/TE/flip angle = 34 ms/12 ms/50 deg., 256 x 256 matrix, 1 mm effective slice thickness, 150 mm field of view, and one signal acquisition. Sequential vertical coronal sections were taken against the skull base. The anterior septal vein, the medial atrial vein, the anterior caudate vein and thalamostriate vein were detected in all subjects. In all clinical cases, HR-MRV was equal in diagnostic capability to conventional cerebral angiography.

منابع مشابه

High Resolution Functional MR Venography with 7T MRI

Magnetic resonance venography (MRV) has been used to assess the effects of medical treatment for and the resolution of cerebral venous diseases. The contrast mechanism involving MRV used for functional or anatomical applications has been based on the local magnetic field inhomogeneity created by deoxyhemoglobin, which determines MR signal intensity [1,2]. Susceptibility weighted imaging (SWI), ...

متن کامل

High-resolution pulmonary arterio- and venography using multiple-bolus multiphase 3D-Gd-mRA.

The purpose of this study was to demonstrate selective visualization of pulmonary arteries and veins with high spatial resolution for improved detection of vascular pathologies. Time-resolved pulmonary three-dimensional gadolinium-enhanced magnetic resonance angiograms (3D-Gd-MRA) were acquired with an ultrashort 3D fast low-angle shot (FLASH) sequence (TR/TE 2.3/0.9 msec) using asymmetric k-sp...

متن کامل

dIagnostIc accuracy of doppler sonography and magnetIc resonance venography for the assessment of ImpaIred outflow from the Internal jugular veIn In patIents wIth multIple sclerosIs

Objectives: This prospective study was aimed at evaluation of diagnostic value of Doppler sonography and magnetic resonance (MR) venography in the internal jugular vein territory. Material and methods: There were assessed 126 patients (252 internal jugular veins). The patients were initially diagnosed using Doppler sonography and MR venography, and then catheter venography of the veins was perf...

متن کامل

Tissue Selective Magnetic Resonance Subtraction Venography

We have developed a procedure to image the major veins of the brain using three dimensional magnetic resonance imaging sequences. This procedure is based on the selective enhancement of blood vessels following intravenous administration of contrast media such as gadolinium. A simple subtraction is performed between the post-contrast and pre-contrast MR images after correcting for overall intens...

متن کامل

Why should we report posterior fossa emissary veins?

Posterior fossa emissary veins are valveless veins that pass through cranial apertures. They participate in extracranial venous drainage of the posterior fossa dural sinuses. The mastoid emissary vein, condylar veins, occipital emissary vein, and petrosquamosal sinus are the major posterior fossa emissary veins. We believe that posterior fossa emissary veins can be detected by radiologists befo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • Acta medica Okayama

دوره 51 6  شماره 

صفحات  -

تاریخ انتشار 1997