Dynamic digital phantoms

ثبت نشده
چکیده

The construction parameters and the composition of phantoms are strictly specified. Hence comparing the results from repeated imaging of a phantom with different imaging parameters allows isolation of the effect of the varied parameter. With this knowledge one can assign settings for optimum imaging of that particular phantom. Ideally the phantom would be exactly the same for every scan to allow easy comparison. However in some cases natural degradation of the materials involved means that the results will change slowly over time and designers of phantoms often attempt to select materials to reduce this degradation. However the nature of the physical processes involved in the imaging modality limits the range of possible materials available for construction, potentially making it impossible to eliminate degradation. This is especially true in the case of multi-modality phantoms in which the material choice may be very severely limited. However, if the degradation is very slow, is measured before use or is factored into the image evaluation, then it can be managed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Introducing a bony composite as tissue equivalent for radiotherapy phantoms

The use of a device that simulates the actual condition, as well as being equivalent to the human body in materials and tissues, and having the capability of acting like internal motions of human body is necessary to investigate and simulate the motion of a tumor in radiotherapy and to evaluate dosimetrical coverage of the dynamic target. This device which is called the dynamic phantom should s...

متن کامل

A 5D computational phantom for pharmacokinetic simulation studies in dynamic emission tomography

INTRODUCTION Dynamic image acquisition protocols are increasingly used in emission tomography for drug development and clinical research. As such, there is a need for computational phantoms to accurately describe both the spatial and temporal distribution of radiotracers, also accounting for periodic and non-periodic physiological processes occurring during data acquisition. METHODS A new 5D ...

متن کامل

Silicone breast phantoms for elastographic imaging evaluation.

PURPOSE Breast cancer is a major public health issue for women, and early detection significantly increases survival rate. Currently, there is increased research interest in elastographic soft-tissue imaging techniques based on the correlation between pathology and mechanical stiffness. Anthropomorphic breast phantoms are critical for ex vivo validation of emerging elastographic technologies. T...

متن کامل

Digital-signal-processor-based dynamic imaging system for optical tomography.

In this article, we introduce a dynamic optical tomography system that is, unlike currently available analog instrumentation, based on digital data acquisition and filtering techniques. At the core of this continuous wave instrument is a digital signal processor (DSP) that collects, collates, processes, and filters the digitized data set. The processor is also responsible for managing system ti...

متن کامل

Dynamic Simulation of CNTFET-Based Digital Circuits

   In this paper we propose a simulation study to carry out dynamic analysis of CNTFET-based digital circuit, introducing in the semi-empirical compact model for CNTFETs, already proposed by us, both the quantum capacitance effects and the sub-threshold currents. To verify the validity of the obtained results, a comparison with Wong model was carried out. Our mode...

متن کامل

Pharmacokinetic digital phantoms for accuracy assessment of image-based dosimetry in (177)Lu-DOTATATE peptide receptor radionuclide therapy.

Patient-specific image-based dosimetry is considered to be a useful tool to limit toxicity associated with peptide receptor radionuclide therapy (PRRT). To facilitate the establishment and reliability of absorbed-dose response relationships, it is essential to assess the accuracy of dosimetry in clinically realistic scenarios. To this end, we developed pharmacokinetic digital phantoms correspon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011