Use of an inclinometer to measure flexibility of the iliotibial band using the Ober test and the modified Ober test: differences in magnitude and reliability of measurements.

نویسندگان

  • Nancy B Reese
  • William D Bandy
چکیده

STUDY DESIGN Test-retest design to evaluate the reliability of the measurement of iliotibial (IT) band flexibility using an inclinometer to measure the hip adduction angle. OBJECTIVES The primary objective was to determine the intrarater reliability of the Ober test and the modified Ober test for the assessment of IT band flexibility using an inclinometer to measure the hip adduction angle. A secondary objective was to determine if a difference existed between the measurements of IT band flexibility between the Ober and modified Ober test. BACKGROUND The Ober test and the modified Ober test are frequently used for the measurement of IT band flexibility. To date, data documenting the objective measurement of flexibility of the IT band is scarce in the literature. METHODS AND MEASURES Sixty-one subjects, with a mean age of 24.2 (SD = 4.3) years, were measured during 2 measurement sessions over 2 consecutive days. During each measurement session, subjects were positioned on their left side and, with an inclinometer at the lateral epicondyle of the femur, hip adduction was measured during the Ober test (knee at 90 degrees of flexion) and the modified Ober test (knee extended). If the limb was horizontal, it was considered to be at 0 degrees, if below horizontal (adducted), it was recorded as a positive number, and if above horizontal (abducted), it was recorded as a negative number. RESULTS The ICC values calculated for the intrarater reliability of the repeated measurement were 0.90 for the Ober test and 0.91 for the modified Ober test. Results of the dependent t test indicated a significantly greater range of motion of the hip in adduction using the modified Ober test as compared to the Ober test. DISCUSSION AND CONCLUSION The use of an inclinometer to measure hip adduction using both the Ober test and the modified Ober test appears to be a reliable method for the measurement of IT band flexibility, and the technique is quite easy to use. However, given that the modified Ober test allows significantly greater hip adduction range of motion than the Ober test, the 2 examination procedures should not be used interchangeably for the measurement of the flexibility of the IT band.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Reliability of Bubble Inclinometer and Tape Measure in Determining Lumbar Spine Range of Motion in Healthy Individuals and Patients

Purpose: Regarding the high prevalence of low back pain in various communities and the need to determine an appropriate treatment plan for these patients, examining their functional limitation and disability level is of utmost importance. In this regard, one of the important indicators is Lumbar range of motion. Measurement of the range of motion is a common and appropriate method for determini...

متن کامل

Reliability of Measuring Lumbar Lordosis, Flexion and Extension Using Dual Inclinometer in Healthy Subjects and Patients with Non-Specific Chronic Low Back Pain

Objective: Accurate assessment of lumbar range of motion is of great value for both evaluating lumbar functions and monitoring treatment progress. Recent research indicates that there is no general consensus on the most valid and reliable method of measuring spinal range of motion. The purpose of this study was to determine the intra-rater reliability of lumbar flexion and extension measurement...

متن کامل

Iliotibial Band Anatomy And Biomechanics, Implications For The Treatment Of Iliotibial Band Syndrome

METHODS: Gross anatomical studies of 20 embalmed cadavers that examined origins, insertions and significant attachments of the ITB were performed. The strain generated in the ITB by three typical stretching manoeuvres (Obers test: OBER, Hip flexion, adduction and external loading: HIP, Straight leg raise: SLR) was measured in 5 unembalmed cadavers using foil-type strain gauges. An ultrasound as...

متن کامل

اعتبار و تکرارپذیری Dual Digital Inclinometer در اندازه گیری زاویه کایفوز پشتی در زنان بالای 45 سال

Objective: Accurate measurement of thoracic kyphosis has high value in the evaluation of patients with spinal kyphosis and in assessing the effectiveness of different treatment methods. Recently, Dual Digital Inclinometer (DDI) has introduced as a non-invasive tool that can measure the kyphosis angle. According to available information there is only one published study regarding the validity an...

متن کامل

The Effect of Eight-Week Corrective Exercises Carried out in Water on Pain, Neck Flexors Endurance and Upper Extremity Range of Motion in Patient with Upper Crossed Syndrome

Introduction: Lifestyle and the constant use of communication technologies have led to the upper crossed syndrome. The purpose of this study was to investigate of the effect of comprehensive corrective exercises carried out in water on pain, neck flexors muscles endurance and neck and upper extremity Range of Motion (ROM) in the patients with upper crossed syndrome (UCS). Methods: In this semi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of orthopaedic and sports physical therapy

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 2003