Diabetes Antibody Standardization Program: first assay proficiency evaluation.

نویسندگان

  • Polly J Bingley
  • Ezio Bonifacio
  • Patricia W Mueller
چکیده

The aims of the first proficiency evaluation of the Diabetes Antibody Standardization Program (DASP) were to assess general implementation of assay methods and to evaluate the new World Health Organization (WHO) reference reagent for autoantibodies to GAD and IA-2. Forty-six laboratories in 13 countries received coded sera from 50 patients with newly diagnosed type 1 diabetes and 50 blood donor control subjects, together with the WHO reference reagent and diluent serum. Results were analyzed using receiver operator characteristic (ROC) curves. Sensitivity was adjusted to 90% specificity in workshop controls. The median adjusted sensitivity for GADA (45 laboratories) was 84% (range 62-96%), for IA-2A (43 laboratories) was 58% (50-74%), and for insulin autoantibody (IAA; 23 laboratories) was 36% (13-66%). ROC curve analysis showed all GADA and IA-2A assays, and 18/23 IAA assays found significant differences between patients and control subjects. There was good concordance between laboratories in ranking of samples by GADA and IA-2A levels or if results were expressed in relation to the WHO reference reagent. Assays that achieved the highest sensitivity for IAA were also concordant in ranking samples, but overall concordance for IAA was poor. Differences in assay protocols between laboratories must be addressed so that all centers and kit manufacturers can perform to the same high standard.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diabetes antibody standardization program: first proficiency evaluation of assays for autoantibodies to zinc transporter 8.

BACKGROUND Zinc transporter 8 (ZnT8) is a recently identified major autoantigen in type 1 diabetes, and autoantibodies to ZnT8 (ZnT8A) are new markers for disease prediction and diagnosis. Here we report the results of the first international proficiency evaluation of ZnT8A assays by the Diabetes Antibody Standardization Program (DASP). METHODS After a pilot workshop in 2007, an expanded ZnT8...

متن کامل

Diabetes Antibody Standardization Program

OBJECTIVE Autoantibodies to IA-2β (IA-2βA) are important risk markers of type 1 diabetes. We report the first Diabetes Antibody Standardization Program (DASP) evaluation of IA-2βA assays. RESEARCH DESIGN AND METHODS Thirteen laboratories from nine countries received coded sera from 50 patients with newly diagnosed type 1 diabetes and 100 healthy blood donors. IA-2βA results were analyzed usin...

متن کامل

Analysis of point-of-care and over-the-counter testing methods for hemoglobin A1c: how good do they need to be?

In this issue of Journal of Diabetes Science and Technology, Chang and colleagues evaluate the performance of the A1CNow® SELFCHECK device for measurement of hemoglobin A1c (HbA1c). The authors discuss the potential advantages of point-of-care (POC) HbA1c testing and also mention the importance of accuracy and precision and provide some data to document the device's performance. There are speci...

متن کامل

Standardization of an Enzyme-Linked Immunosorbent Assay for Detection of Infectious Bronchitis Virus Antibody.

An indirect enzyme–linked immunosorbent assay (ELISA) was developed for screening of antibody to avian infectious bronchitis virus (IBV). Antigen was prepared from whole-purified IBV Massachusetts serotype (BR 801 strain). Optimum dilution with minimum background for antigen concentration, rabbit anti-chicken conjugate and sera in developed ELISA was determined 0.1μg/ml, 1:3000 and 1:100, respe...

متن کامل

Multi-center evaluation of analytical performance of the microparticle enzyme immunoassay for sirolimus.

OBJECTIVES This study evaluated the analytical characteristics of the new Abbott microparticle enzyme immunoassay (MEIA) for sirolimus. DESIGN AND METHODS The protocol consisted of nine sections: evaluation of antibody specificity, linearity, detection limit, quantification limit, endogenous interferents, exogenous interferents, precision, proficiency testing panel, and method comparison. R...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes

دوره 52 5  شماره 

صفحات  -

تاریخ انتشار 2003