Laboratory Corrosion Testing of Medical Implants

نویسنده

  • Richard A. Corbett
چکیده

Performance evaluation of implantable devices is not new to medical device manufacturers, specifically implant manufacturers. A focus on corrosion resistance of implant devices has prompted members of the medical device industry, along with the United States Food and Drug Administration [USFDA] to set forth a guide for performance testing. Although actual corrosion resistance of a material can only be proven through long-term clinical trials, accelerated laboratory tests can be used to predict certain effects. Because corrosion of metals is an electrochemical process, accepted electrochemical testing techniques are used very effectively in the CPI (Chemical Process Industry) [namely ASTM G5, G61, and G71] have been adopted for use. Inconsistencies among laboratories, employing differing protocols, have resulted in varying interpretations by even the most experienced electrochemists and corrosion scientists. Some of the most widely used standard tests are also the most widely abused and misinterpreted, especially by persons who are less aware of materials properties. Since the USFDA provides no clear direction to testing, a modified electrochemical standard [ASTM F2129] has been adopted to address concerns regarding test environment, voltage scan rate, device configuration, and test protocol. The remaining issue is the establishment of an acceptance criterion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Assessment of Astm F 2129 Electrochemical Testing of Small Medical Implants - Lessons Learned

Much has been learned over a short period of time with respect to the corrosion assessment of small medical implant devices. Laboratory testing started with modifications of ASTM G 5 and G 61, which lead to the development of ASTM F 2129, and thence the fine-tuning of that specification to meet the intent of the FDA Guideline for non-clinical tests. The changes in electrochemical testing protoc...

متن کامل

Metallic Medical Implants: Electrochemical Characterization of Corrosion Processes

whole range of medical implants is justified by their superior mechanical properties (hardness, stiffness, etc.) compared, for example, to polymers. Other properties like biocompatibility or visibility in X-ray images also can be mentioned. One of their drawbacks is that electrochemical reactions take place on metallic surfaces in the human body. To replicate the real environment as closely as ...

متن کامل

Interference of magnesium corrosion with tetrazolium-based cytotoxicity assays.

Magnesium (Mg) alloys are promising materials for the development of biodegradable implants. However, the current in vitro test procedures for cytotoxicity, cell viability and proliferation are not always suitable for this class of materials. In this paper we show that tetrazolium-salt-based assays, which are widely used in practice, are influenced by the corrosion products of Mg-based alloys. ...

متن کامل

In Vivo Corrosion of Two Novel Magnesium Alloys ZEK100 and AX30 and Their Mechanical Suitability as Biodegradable Implants

In magnesium alloys, the components used modify the alloy properties. For magnesium implants in contact with bone, rare earths alloys are commonly examined. These were shown to have a higher corrosion resistance than other alloys and a high mechanical strength, but their exact composition is hard to predict. Therefore a reduction of their content could be favorable. The alloys ZEK100 and AX30 h...

متن کامل

The corrosion scenario in human body: Stainless steel 316L orthopaedic implants

As the world’s populations increase and age, there is a parallel increase in the number of medical procedures addressed to bone related injuries. It is estimated that approximately 1 million of orthopaedic implant surgeries in association with total joint replacements are needed every year. This number is expected to double between 1999 and 2025 as a result of increasing numbers of musculoskele...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004