Thromboembolic stroke in patients with a HeartMate-II left ventricular assist device – the role of anticoagulation

نویسندگان

  • Walter M. van den Bergh
  • Annemieke Oude Lansink-Hartgring
  • Abram L. van Duijn
  • Annemarie E. Engström
  • Jaap R. Lahpor
  • Arjen JC Slooter
چکیده

BACKGROUND AND PURPOSE It is unknown what the optimal anticoagulant level is to prevent thromboembolic stroke in patients with left ventricular assist device (LVAD) support. We aimed to evaluate the relation between coagulation status and the occurrence of thromboembolic stroke in HeartMate-II LVAD assisted patients. METHODS Thirty-eight consecutive patients with a HeartMate-II LVAD were included. Coagulation status was classified according to INR and aPTT ratio at: 1) the moment of first thromboembolic stroke; and 2) during the two weeks preceding the first thromboembolic stroke to assess long-term coagulation status. In patients without stroke, coagulation status was determined just before heart transplant, VAD explantation or death, whichever came first, and at two weeks preceding these surrogate endpoints. Based on coagulation status, patients were divided in two groups: Group I (reference group) was defined as INR below 2 and aPTT ratio below 1.5; Group II (adequate anticoagulation) as INR above 2 or aPTT ratio above 1.5. Logistic regression analysis was performed to assess the odds ratio for developing stroke for patients with adequate anticoagulation compared to the reference Group. RESULTS Thromboembolic stroke occurred in six (16 %) patients, none within 2 weeks after LVAD implantation. Considering coagulation status at the time of event, patients in coagulation Group II had no decreased risk for thromboembolic stroke (OR 0.78; 95 % CI 0.12-5.0). Results for coagulation status 2 weeks prior of event could not be calculated as all six strokes occurred in Group II. CONCLUSION In our experience anticoagulation within predefined targets is not associated with a reduced thromboembolic stroke risk in patients with a HeartMate-II LVAD on antiplatelet therapy. However, no firm statement about the effect of either anticoagulant or antiaggregant therapy can be made based on our study. A larger randomized study is needed to support the hypothesis that there may be no additional benefit of coumarin or heparin therapy compared with antiplatelet therapy alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.

BACKGROUND Right heart dysfunction confers significant morbidity and mortality after left ventricular assist device implantation and historically occurs in as many as a third of patients. It is unknown whether newer axial flow pumps have a different impact on postimplant right heart dysfunction. We compared the incidence of right heart dysfunction after implantation of the pulsatile HeartMate I...

متن کامل

Acquired von Willebrand syndrome in patients with a centrifugal or axial continuous flow left ventricular assist device.

OBJECTIVES The aim of this study was to determine whether differences in continuous flow left ventricular assist devices (LVADs) may lead to differences in the von Willebrand profile and the occurrence of bleeding and thromboembolic events. BACKGROUND The HeartMate II (Thoratec Corp., Pleasanton, California) and HeartWare Ventricular Assist Device (HVAD) (HeartWare, Inc., Framingham, Massachu...

متن کامل

Pre-operative risk factors of bleeding and stroke during left ventricular assist device support: an analysis of more than 900 HeartMate II outpatients.

OBJECTIVES This study sought to determine the pre-operative risk factors related to late bleeding, stroke, and pump thrombosis in patients with HeartMate II (HMII) left ventricular assist devices (LVADs) (Thoratec Corporation, Pleasanton, California) that might influence tailored improvements in patient management. BACKGROUND Adverse events in LVAD patients remain high. It is unclear whether ...

متن کامل

Survival after left ventricular assist device with and without temporary right ventricular support.

BACKGROUND Right ventricular (RV) failure after the insertion of a left ventricular assist device (LVAD) historically results in poor outcomes. Patients requiring temporary RV support after LVAD insertion are a heterogeneous group of patients consisting of those in cardiogenic shock after myocardial infarction, to those with chronic decompensated heart failure. For patients requiring biventricu...

متن کامل

Haemolysis as a first sign of thromboembolic event and acute pump thrombosis in patients with the continuous-flow left ventricular assist device HeartMate II

BACKGROUND Despite advances in pump technology, thromboembolic events/acute pump thrombosis remain potentially life-threatening complications in patients with continuous-flow left ventricular assist devices (CF-LVAD). We sought to determine early signs of thromboembolic event/pump thrombosis in patients with CF-LVAD, which could lead to earlier intervention. METHODS We analysed all HeartMate ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015