Dual-energy X-ray absorptiometry measured regional body composition least significant change: effect of region of interest and gender in athletes.

نویسندگان

  • Bjoern Buehring
  • Diane Krueger
  • Jessie Libber
  • Bryan Heiderscheit
  • Jennifer Sanfilippo
  • Brian Johnson
  • Irina Haller
  • Neil Binkley
چکیده

Dual-energy X-ray absorptiometry (DXA) is widely used to evaluate body composition in athletes. Knowledge of measurement precision is essential for monitoring body composition changes over time. This study begins characterizing DXA body composition precision in 60 (30 males and 30 females) Division 1 athletes focusing on gender, regional, and tissue type differences. Two total body scans with repositioning between were performed on the same day. Least significant change (LSC) for the root-mean-square deviation (LSCRMSD) and the percent coefficient of variation (LSC%CV) for total, lean, and fat mass was calculated for 6 regions of interest. The effect of gender, region, tissue type, and mass on the standard deviation (SD) and percent coefficient of variation (%CV) between the 2 scans was evaluated using repeated measures regression analysis. Statistically significant effects of gender, region, tissue type, and mass on SD and %CV were noted. To generalize, a nonlinear positive relationship between LSCRMSD and mass and a nonlinear negative relationship between LSC%CV and mass were observed. In conclusion, DXA body composition LSC varies among genders, regions, tissues, and mass. As such, when evaluating serial body composition in athletes, especially if assessing regional change, knowledge of precision in individuals of similar body size and gender to the population of interest is needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

Dual-energy X-ray absorptiometry diagnostic discordance between Z-scores and T-scores in a young Iranian population

  Background: Dual-energy X-ray Absorptiometry (DXA) is considered the gold standard for non-invasive measurement of bone mass. T-scores and Z-scores are used to present the results of bone mass. The present study was designed to evaluate the discordance between T-scores and Z-scores calculated at a same level and its relation with age, gender and body mass index (BMI) in a representative sampl...

متن کامل

Analysis of Dietary Intake and Body Composition of Female Athletes over a Competitive Season

Th e purpose of the study was to examine dietary intake, body composition and bone mineral density changes at the beginning and end of a competitive season in female athletes of sports that have been less represented in the literature. NCAA Division I basketball (n=10) and soft ball (n=10) players mean age (20±1 years) completed 3-day food records at the beginning and end of season. Body compos...

متن کامل

Effects of daily activities on dual-energy X-ray absorptiometry measurements of body composition in active people.

PURPOSE Dual-energy x-ray absorptiometry (DXA) is becoming a popular tool to measure body composition in athletes, owing to its ease of operation and comprehensive analysis of body composition. This study represents the first systematic investigation of the reliability of DXA measurements of body composition in trained individuals and includes measurements of daily variability as well as the sp...

متن کامل

Comparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis

Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry

دوره 17 1  شماره 

صفحات  -

تاریخ انتشار 2014