Clinical response with adaptive CRT algorithm compared with CRT with echocardiography-optimized atrioventricular delay: a retrospective analysis of multicentre trials.

نویسندگان

  • Jagmeet P Singh
  • William T Abraham
  • Eugene S Chung
  • Tyson Rogers
  • Alex Sambelashvili
  • James A Coles
  • David O Martin
چکیده

AIMS Adaptive cardiac resynchronization therapy (aCRT) is a novel algorithm for CRT pacing that provides automatic ambulatory selection between synchronized left ventricular (LV) or bi-ventricular (BiV) pacing and optimization of atrioventricular (AV) and inter-ventricular (VV) delays based on periodic measurement of intrinsic conduction. We aimed to compare the clinical response between aCRT and standard CRT in historical trials. METHODS AND RESULTS The treatment arm of the aCRT trial was compared with a pooled historical control (HC) derived from the CRT arms of four clinical trials (MIRACLE, MIRACLE ICD, PROSPECT, and InSync III Marquis) with respect to the proportion of patients who had an improved clinical composite score (CCS) at the 6-month follow-up. Patients in the HC underwent echocardiography-guided AV optimization after the implant. A propensity score model was used to adjust for 22 potential baseline confounders of the effect of CRT. Patients were stratified into quintiles according to the propensity score and the adjusted absolute treatment effect was obtained by averaging estimates across these quintiles. The propensity score model included 751 patients (aCRT: 266, historical trials: 485). The adjusted absolute difference in percent improved in CCS between the aCRT and HC arms was 11.9% [95% confidence interval (CI): 2.7-19.2%] favouring aCRT. The patients in the aCRT group were significantly more likely to have an improved CCS than the patients in the HC (odds ratio = 1.65, 95% CI: 1.1-2.5). CONCLUSION The aCRT algorithm may be associated with additional improvement in clinical response compared with historical CRT with echocardiographic AV optimization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomized prospective trial of atrioventricular delay programming for cardiac resynchronization therapy.

OBJECTIVES The purpose of this study was to determine if AV delay optimization with continuous-wave Doppler aortic velocity-time integral (VTI) is clinically superior to an empiric program in patients treated with cardiac resynchronization therapy (CRT) for severe heart failure. BACKGROUND The impact of AV delay programming on clinical outcomes associated with CRT is unknown. METHODS A rand...

متن کامل

Left univentricular pacing for cardiac resynchronization therapy using rate-adaptive atrioventricular delay

OBJECTIVE To evaluate left univentricular (LUV) pacing for cardiac resynchronization therapy (CRT) using a rate-adaptive atrioventricular delay (RAAVD) algorithm to track physiological atrioventricular delay (AVD). METHODS A total of 72 patients with congestive heart failure (CHF) were randomized to RAAVD LUV pacing versus standard biventricular (BiV) pacing in a 1: 1 ratio. Echocardiography ...

متن کامل

Doppler echocardiographic methods for optimization of the atrioventricular delay during cardiac resynchronization therapy.

Cardiac resynchronization therapy (CRT) is beneficial for a majority of patients with medically refractory heart failure due to severe left ventricular (LV) systolic dysfunction and prolonged interventricular conduction to improve symptoms and LV performance. An optimally programmed atrioventricular delay (AVD) during CRT can be also important to maximize the response in left ventricular functi...

متن کامل

Adaptive cardiac resynchronization therapy device: a simulation report.

We report the results of a simulation of an adaptive cardiac resynchronization therapy (CRT) device performing biventricular pacing in which the atrioventricular (AV) delay and interventricular (VV) interval parameters are changed dynamically in response to data provided by the simulated IEGMs and simulated hemodynamic sensors. A learning module, an artificial neural network, performs the adapt...

متن کامل

Echocardiography for cardiac resynchronization therapy: recommendations for performance and reporting--a report from the American Society of Echocardiography Dyssynchrony Writing Group endorsed by the Heart Rhythm Society.

Echocardiography plays an evolving and important role in the care of heart failure patients treated with biventricular pacing, or cardiac resynchronization therapy (CRT). Numerous recent published reports have utilized echocardiographic techniques to potentially aide in patient selection for CRT prior to implantation and to optimized device settings afterwards. However, no ideal approach has ye...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 15 11  شماره 

صفحات  -

تاریخ انتشار 2013